hps+ ultrasonic level sensors-1

Extract from our online catalogue: hps+ ultrasonic sensors Current to: 2025-01-27 microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E [email protected] microsonic® is a registered trademark of microsonic GmbH. All rights reserved.

 Open the catalog to page 1
hps+ ultrasonic level sensors-2

hps+ in safety gear - When you need chemically resistant, pressure-resistant sensors. > Optionally used in normal pressure or overpressure > PTFE membrane > for protection against aggressive media > Stainless-steel or optional PVDF housing for hps+340 > for use in the food industry > Sealed against the housing with an O-ring made from FFKM > for the highest possible chemical resistance > Digital display with direct measured value output in mm/cm or % > Numeric configuration of the sensor using digital display > UL Listed to Canadian and US safety standards > 2 switching outputs in pnp variant...

 Open the catalog to page 2
hps+ ultrasonic level sensors-3

Description For fill level measurements of aggressive media and in overpressure the ultrasonic transducers of the new hps+ sensors are now fitted out - as standard - with a PTFE film. It is sealed with a FFKM O-ring against the housing made of 1.4571 stainless steel or PVDF. This ensures a high degree of resistance to aggressive media. Fill level measurement in tanks The hps+ sensors can be used for fill level measurement under normal pressure or in tanks and containers with an overpressure of up to 6 bar. Its special software filters also allow its use in containers filled from above or that have...

 Open the catalog to page 3
hps+ ultrasonic level sensors-4

2 switching outputs in pnp switching technology 1 analogue output with an additional pnp switching output The hps+ sensors with switching output have three operating modes:  Single switching point Two-way reflective barrier Window mode Two three-colour LEDs always show the current state of the switching outputs or the analogue output. With TouchControl all configuration can be done right at the sensor. The easily legible three-digit LED display continually shows the current distance value and automatically switches between millimetre and centimetre displays. Setting a switching or analogue output...

 Open the catalog to page 4
hps+ ultrasonic level sensors-5

detection zone scale drawing design process connection G1 operating mode proximity switch/reflective mode reflective barrier window mode particularities druckfest bis 6 bar Uberdruck hohe Chemiebestandigkeit ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range by normal pressure maximum range by > 2 bar overpressure accuracy echo propagation time measurement ± 1 % (temperature drift internally compensated)

 Open the catalog to page 5
hps+ ultrasonic level sensors-6

electrical data operating voltage UB 9 - 30 V d.c., reverse polarity protection no-load current consumption < 80 mA type of connection 5-pin M12 initiator plug hps+ ultrasonic sensors

 Open the catalog to page 6
hps+ ultrasonic level sensors-7

output 1 switching output NOC/NCC adjustable, short-circuit-proof output 2 switching output NOC/NCC adjustable, short-circuit-proof delay prior to availability < 300 ms synchronisation input ultrasonic transducer operating temperature storage temperature stainless steel, plastic parts: PBT, TPU coated with PTFE film, FFKM O-ring IP 67 technical features/characteristics controls 2 push-buttons + LED display (TouchControl) scope for settings Teach-in and numeric configuration via TouchControl indicators 3-digit LED display, 2 x three-colour LED particularities druckfest bis 6 bar Uberdruck hohe...

 Open the catalog to page 7
hps+ ultrasonic level sensors-8

The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features. hps+ ultrasonic sensors

 Open the catalog to page 8
hps+ ultrasonic level sensors-9

detection zone measuring range operating mode proximity switch/reflective mode reflective barrier window mode analogue distance measurement druckfest bis 6 bar Überdruck hohe Chemiebeständigkeit Edelstahlausführung Display Prozessanschluss G1 UL Listed ultrasonic-specific means of measurement echo propagation time measurement transducer frequency blind zone operating range maximum range by normal pressure maximum range by ≥ 2 bar overpressure 0.025 mm to 0.30 mm, depending on the analogue window ± 1 % (temperature drift internally compensated)

 Open the catalog to page 9
hps+ ultrasonic level sensors-10

electrical data operating voltage UB 9 - 30 V d.c., reverse polarity protection no-load current consumption < 80 mA type of connection 5-pin M12 initiator plug hps+ ultrasonic sensors

 Open the catalog to page 10
hps+ ultrasonic level sensors-11

output 1 analogue output current: 4-20 mA / voltage: 0-10 V, short-circuit-proof switchable rising/falling output 2 switching output NOC/NCC adjustable, short-circuit-proof delay prior to availability < 300 ms synchronisation input ultrasonic transducer operating temperature storage temperature stainless steel, plastic parts: PBT, TPU coated with PTFE film, FFKM O-ring IP 67 technical features/characteristics controls 2 push-buttons + LED display (TouchControl) scope for settings Teach-in and numeric configuration via TouchControl indicators 3-digit LED display, 2 x three-colour LED particularities...

 Open the catalog to page 11
hps+ ultrasonic level sensors-12

The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features. hps+ ultrasonic sensors

 Open the catalog to page 12
hps+ ultrasonic level sensors-13

detection zone scale drawing design process connection G1 operating mode proximity switch/reflective mode reflective barrier window mode particularities druckfest bis 6 bar Uberdruck hohe Chemiebestandigkeit ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range by normal pressure maximum range by > 2 bar overpressure echo propagation time measurement 0.18 mm to 0.45 mm, depending on the analogue window ± 0.15 % ± 1 % (temperature drift internally compensated)

 Open the catalog to page 13
hps+ ultrasonic level sensors-14

electrical data operating voltage UB 9 - 30 V d.c., reverse polarity protection no-load current consumption < 80 mA type of connection 5-pin M12 initiator plug hps+ ultrasonic sensors

 Open the catalog to page 14
hps+ ultrasonic level sensors-15

output 1 switching output NOC/NCC adjustable, short-circuit-proof output 2 switching output NOC/NCC adjustable, short-circuit-proof delay prior to availability < 300 ms synchronisation input ultrasonic transducer operating temperature storage temperature stainless steel, plastic parts: PBT, TPU coated with PTFE film, FFKM O-ring IP 67 technical features/characteristics controls 2 push-buttons + LED display (TouchControl) scope for settings Teach-in and numeric configuration via TouchControl indicators 3-digit LED display, 2 x three-colour LED particularities druckfest bis 6 bar Uberdruck hohe...

 Open the catalog to page 15
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.