crm+ ultrasonic level sensors
75Pages

{{requestButtons}}

Catalog excerpts

crm+ ultrasonic level sensors - 1

EVERY THING ULTRA SONIC Extract from our online catalogue: crm+ ultrasonic sensors Current to: 2023-1 1-13 microsonic GmbH / PhoenixseestraRe 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E info@microsonic.de microsonic® is a registered trademark of microsonic GmbH. All rights reserved.

Open the catalog to page 1
crm+ ultrasonic level sensors - 2

Wear-resistant PEEK film protects the sensor membrane from chemicals, contamination and caking. Ultrasonic transducer protected by PEEK film Stainless-steel housing Digital display with direct measured value output in mm/cm or % IO-Link interface Numeric configuration of the sensor using digital display Automatic synchronisation and multiplex operation for simple cleaning and high resistance to wear for support of the new industry standard permits the complete advance configuration of the sensor for simultaneous operation of up to ten sensors in close quarters 1 Push-Pull switching output 1 or...

Open the catalog to page 2
crm+ ultrasonic level sensors - 3

Description Sensor membrane with wear-resistant protective film In many filling processes, spray on the sensor membrane simply cannot be avoided. These sprays often harden so that after longer periods of operation contamination can only be removed from the sensor membrane by mechanical means. The new protective film of the crm+ sensors now makes it easy to remove caked-on soiling, such as hardened casting compound and cement spatter. The protective film is also highly resistant to corrosive media. The threaded sleeve is made of 1.4571 stainless steel. TouchControl with LED display -...

Open the catalog to page 3
crm+ ultrasonic level sensors - 4

distance value and automatically switches between millimetre and centimetre displays. Setting a switching or analogue output can optionally be carried out by numeric input of the desired distance values, or using a teach-in procedure. This permits the user to select the configuration method preferred. The crm+ sensors support synchronisation and multiplex operation and have extensive parameterisation options via LinkControl. For detailed information, please see at mic+ sensors . LinkControl consists of the LinkControl adapter and the LinkControl software and facilitates the configuration of...

Open the catalog to page 4
crm+ ultrasonic level sensors - 5

scale drawing detection zone 1 x Push-Pull measuring range design operating mode particularities ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy 30 - 350 mm cylindrical M30 lO-Link proximity switch/reflective mode reflective barrier window mode high chemical resistance stainless steel version display IO-Link version 1.1 Smart Sensor Profile UL listed echo propagation time measurement 320 kHz 30 mm 250 mm 350 mm 0.10 mm ± 0.15 % ± 1 % (temperature drift internally compensated) electrical data operating...

Open the catalog to page 5
crm+ ultrasonic level sensors - 6

micro/onic crm+ ultrasonic sensors

Open the catalog to page 6
crm+ ultrasonic level sensors - 8

technical features/characteristics temperature compensation controls scope for settings Synchronisation multiplex indicators particularities yes 2 push-buttons + LED display (TouchControl) Teach-in and numeric configuration via TouchControl LCA-2 with LinkControl IO-Link yes yes 3-digit LED display, 2 x three-colour LED high chemical resistance stainless steel version display IO-Link version 1.1 Smart Sensor Profile UL listed The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product...

Open the catalog to page 8
crm+ ultrasonic level sensors - 9

scale drawing detection zone 1 x pnp measuring range design operating mode particularities ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy 30 - 350 mm cylindrical M30 proximity switch/reflective mode reflective barrier window mode high chemical resistance stainless steel version display echo propagation time measurement 320 kHz 30 mm 250 mm 350 mm 0.025 mm ± 0.15 % ± 1 % (temperature drift internally compensated) electrical data operating voltage UB 9 - 30 V d.c., reverse polarity protection type of...

Open the catalog to page 9
crm+ ultrasonic level sensors - 11

The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features. crm+ ultrasonic sensors

Open the catalog to page 11
crm+ ultrasonic level sensors - 12

scale drawing detection zone 2 x pnp measuring range design operating mode particularities ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy 30 - 350 mm cylindrical M30 proximity switch/reflective mode reflective barrier window mode high chemical resistance stainless steel version display echo propagation time measurement 320 kHz 30 mm 250 mm 350 mm 0.025 mm ± 0.15 % ± 1 % (temperature drift internally compensated) electrical data operating voltage UB 9 - 30 V d.c., reverse polarity protection type of...

Open the catalog to page 12
crm+ ultrasonic level sensors - 14

The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features. crm+ ultrasonic sensors

Open the catalog to page 14
crm+ ultrasonic level sensors - 15

detection zone scale drawing x analogue 4-20 mA + 0-10 V operating mode analogue distance measurements particularities high chemical resistance stainless steel version display ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy echo propagation time measurement 320 kHz 30 mm 250 mm 350 mm 0.025 mm ± 0.15 % ± 1 % (temperature drift internally compensated) electrical data operating voltage UB 9 - 30 V d.c., reverse polarity protection type of connection 5-pin M12 initiator plug

Open the catalog to page 15
crm+ ultrasonic level sensors - 17

The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features. crm+ ultrasonic sensors

Open the catalog to page 17
crm+ ultrasonic level sensors - 18

scale drawing detection zone 1 x Push-Pull measuring range design operating mode particularities ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy 85 - 600 mm cylindrical M30 lO-Link proximity switch/reflective mode reflective barrier window mode high chemical resistance stainless steel version display IO-Link version 1.1 Smart Sensor Profile UL listed echo propagation time measurement 360 kHz 85 mm 350 mm 600 mm 0.10 mm ± 0.15 % ± 1 % (temperature drift internally compensated) electrical data operating...

Open the catalog to page 18

All Microsonic catalogs and technical brochures

  1. crm+25/D/TC/E

    75 Pages

  2. LCA-2

    11 Pages