Innovation and precision - Micropump - #29

/ 68


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
P. 27
P. 28
P. 29
P. 30
P. 31
P. 32
P. 33
P. 34
P. 35
P. 36
P. 37
P. 38
P. 39
P. 40
P. 41
P. 42
P. 43
P. 44
P. 45
P. 46
P. 47
P. 48
P. 49
P. 50


See other catalogues for Micropump

Text version of the page
Untitled
37 ml/min-13 l/min
PLC compatible interface
with status information for process control systems (the level of the inputs can be configured: 5, 12 or 24 V)
Tube exchange in 5 seconds
Analog
Speed control (0-5 or 0-10V, 0-20 or 4-20mA) Start/Stop, Rotation direction
Autostart
- Speed output
- Digital output (potential free) (Error, okay, busy)
Settings menu
- Configuration of analog interface
- Entry of basic settings, e.g.
- Foot switch control
- Rotation speed (% or rpm)
- Service life of tubing
Timer function, etc.
- Insert the tube (easily and fast)
- Press down the lever (automatically correct pressure setting of the tube)
- Start the pump!
Flow rates / Tubing
Tubing Information
Flow rates in liters/min
Tygon® LFL
PharMed®
Wall
Tubing i.d. (mm)
rpm 5
rpm 10
rpm 50
rpm 100
rpm 200
rpm 300
rpm 400
rpm 500
Order No.
Order No.
(mm)
SC0531
MF0015
3.2
6.4
0.037
0.074
0.37
0.74
1.5
2.2
3.1
3.7
SC0395
MF0016
3.2
9.5
0.08
0.16
0.80
1.6
3.2
4.8
6.4
8.0
SC0396
MF0034
3.2
12.7
0.10
0.20
1.0
2.0
4.0
6.0
8.0
10.0
SC0696
3.2
15.9
0.13
0.26
1.3
2.6
5.2
7.8
10.4
13.0
1-channel delivery processes with large flow rates in clean room areas or a dusty, humid or wet environment.
Approx. values: determined with water, at 22°C, no differential pressure, PharMed tubing
Ordering informat
Model
on
Order No.
Flow rates
Channels
Rollers
Speed
Flowmaster FMT300
ml/min
max.
rpm
230Vac / 50 Hz
ISM 1020
37 -13'000
1
3
5-500
Flowmaster FMT300 115Vac / 50 Hz
ISM 1022
37 - 13'000
1
3
5-500
Accessories
Foot switch (Page 61) IS 10279
Applications
Filling of large volumes of pharmaceutical solution from a seed reactor to bulk vessels under sterile conditions.
Tubing for aggressive media, see Page 35.
sales.ismatec@idexcorp.com You can find your local ISMATEC sales representative at: tq
■afVMfEl*® www.ismatec.com US: +1 360 253 2008 Germany: +49 93 77/92 03 0 29

pageCatalog pdf di En 2012-05-22-31