| | | Return to Noise Index | | |
| | | |
| | | http://www.micronetics.com/Noise_Source/milimeter_wave.pdf | | |
| | | |
| | | | | |
| | | |
| | | Description | | |
| | | |
| | | Waveguide Noise Standards are portable, hand-held "test tools"designed for use in the lab or in the field as part of theAitomatedTest Environment (ATE). Waveguide Noise Standards are compatible with noise figure meters and can be used to test a wide range of parameters. They are also designed to provide an internal calibration function in waveguide equipment and systems. SPECMOAnONS | | |
| | | | | | | | | | | | | | | WAveguide Output Characteristics For Usewith Ncise Figure Meters | | | | MODEL | FREQUENCY | RF OUTPUT EXCESS NOISE RATIO (dB) | FLATNESS TYP. MAX. | POWER REQUIREMENT MAX. | OUTPUT MATES WITH | | | | NSI 1218W | 12.4-18.0 GHz | 15.5 | ±0.5 | ±0.75 | +28V15mA | UG-419/U | | | | NSI 1826W | 18.0-26.5 GHz | 15.5 | ±0.5 | ±0.75 | +28V15mA | UG-595/U | | | | NSI 2640W | 26.5-40.0 GHz | 15.5 | ±0.5 | ±0.75 | +28V15mA | UG-599/U | | | | NSI 51826W | 18.0-26.5 GHz | 25.0 | ±1.5 | ±2.0 | +28V20mA | UG-595/U | | | | NSI 52640W | 26.5-40.0 GHz | 23.0 | ±2.0 | ±3.0 | +28V,20mA | UG-599/U | | | | NSI 53350W | 33.0-50.0 GHz | 21.0 | ±2.0 | ±3.0 | +28V,20mA | UG-383/U | | | | NSI 5565W | 55.0-65.0 GHz | 23.0 | ±2.0 | ±3.0 | +28V,25mA | UG-385/U | | | | NSI 9095W | 90.0-95.0 GHz | 15.0 | ±2.0 | ±2.0 | +28V,40mA | UG-387/U | | | | | | | | Waveguide Output Giaracteristics For Use in Systems | | | | MODEL | FREQUENCY | RF OUTPUT EXCESS NOISE RATIO (dB) | FLATNESS (dB) | POWER REQUIREMENT MAX. | OUTPUT MATES WITH | | | | NSI 7215W | 19.9-23.1 GHz | 25.0 | ±0.6 | +28V,20mA | UG-595/U | | | | NSI 7300W | 29.7-30.3 GHz | 23.0 | ±0.6 | +28V,20mA | UG-599/U | | | | NSI 7315W | 31.2-31.8 GHz | 23.0 | ±0.6 | +28V,20mA | UG-599/U | | | | NSI 7350W | 34.7-35.3 GHz | 23.0 | ±0.6 | +28V,20mA | UG-599/U | | | | | | | | | | | | | | |
| | | |
| | | ■ CperatingTemperature: -55 to+95°C ■ StorageTemperature: -65 to + 125°C ■ SupplyVOltage: +28 VDC ■ Temperature Stability: .015 dB/°C ■ Output Impedance: 50 ohms ■ Peak Factor: 5:1 Applications | | |
| | | ► | | |
| | | |
| | | EMITesting Noise figure measurement | | |
| | | |
| | | |
| | | FOR OUTLINE DRAWINGS REFER TO PAGE 22 | | |
| | | |
| | | MICRONETICS / 26 HAMPSHIRE DRIVE / HUDSON, NH 03051 / TEL: 603-883-2900 / FAX: 603-882-8987 / CUSTOMER HOTLINE: 1-800-963-338 | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | |