:POWER METER - MODEL 3200 - 30868 P OWER M ETER - M ODEL 3200SMARTSENSORThe Model 3200 smart sensor power meter is specifically designed to be integrated into test systems.It features highly accurate complex signal measurement and is controlled with an RS/232 serial interface. You get the flexibility of a power meter that can accuartely measure all digital modulations schemes, such as QPSK 3/4 Coding, QPSK 7/8 Coding, Turbo-coding, 256 QAM, CDMA, and more..., without the fancy packaging or price. Smart Sensor Command Syntax Table 1. Power Meter Alpha Command SetCodeMeaningOutput¹ ID?Instrument identification{G-3200} VR?Version number{VR=1.0} AV?Average number{AV=A}SPECIFICATIONSAV=xAverage. x=A,0 thru 5; =2ˆx{OK}Freqency Range: 10 MHz to 3 GHzPower Range:-60 to -20 dBmTrue Average Power Measurement Bandwidth:20 MHz Relative Measurement Accuracy1 (after temperature stabilization)-20 dBm to -50 dBm: 0.1 dB50 dBm to -55 dBm: 0.2 dB-55 dBm to -60 dBm: 0.4 dBMeasurement Resolution:0.1 dB Display Resolution:Selectable log mode 1, 0.1, 0.01, 0.001 dBSelectable lin mode 2, 3, 4, or 5 significant digitsRF Interface:SMA Connector (Optional Type N)Digital Interface:RS-232 interface with hardware handshakeand a baud rate of 9600.Power RequirementsUT?Units, dBm or pico Watts 2{UT=O} UT=xUnits,0=dBm, l=picoWatts{OK} MS=xTake measurementmeasured power ZEExternal Zero{OK} CA=xExternal Calibration 4{OK} ER?Error status'{OK} no system error or { Exx }All Commands terminate in Table 2. Output Format Table 3. Error Code ListingByte #Data sentMeaning 1Digit 1 (ASCII)Most Significant Data Byte 2Digit 2 (ASCII)Data Byte 22:+15V @ 10mA typ, 25mA max.-15V @ 10mA typ, 25mA max.+5V @ 80mA typ, 200mA max.-5V @ 1mA typ, 5mA max.Dimensions:3.7"W x 5.75"L x 1.5''D Temperature Range:0°C to 50°CTemperature Slew Rate: Considered temperature stabilized whentemperature shifts have been less than 0.1°C/min. for more than 15 minutes.......... n-2Digit x (ASCII)Least Significant DataByte n-1ASCII "CR"Carriage Return n A SCII "LF'Line Feed1Incrorrect syntax or out of range parameters will result in an error.2Linear power is reported as an integer number of picoWatts. Log power isreported in negative dBm with resolution to the 0.1 dBm. The decimal point and the tenths digit are required.30=current measurement, 1=begin new reading using set averaging, 2=continu-ouse output Notes:4The =x is optional. If not sent, power is assumed as -20. Else, command isCA=-42.1 Parameters to be in format identical to measurement output andconsistent with the units selected1Spectral energy above 10 MHz.Relative to reference reading taken within past 15 minutes or 3°C tempera-ture change. Sensor zeroing perfomed every 1 minute or following 1°C tem-perature change for input measurements below -40 dBm.5See attached error code list. Read, {Exx} where xx is error number2Power and grounding arrangement must not induce common mode offsetvoltage at RF connector of greater than 5mv dc or an ac signal greater than20 dB below the minimum signal to be measured. ErrorCodeMeaning 04Input Exceeds system input range 31Serial input rate too high 32FPGA download failed 33RAM test failed 34RAM clear failed 61Invalid command 62Invalid command syntax 63Invalid command input parameter 65Attempt to measure before calibration MICRONETICS/26 HAMPSHIRE DRIVE/ HUDSON, NH 03051 / TEL: 603-883-2900 / FAX: 603-882-8987 WEB: WWW.MICRONETICS.COM |
|