HAND-HELD POWER METER - Micronetics - #1

/ 1


catalogue search
HAND-HELD POWER METER - Micronetics
P. 01
Page:
HAND-HELD POWER METER - Micronetics


See other catalogues for Micronetics

Text version of the page

H

AND

-H

ELD

P

OWER

M

ETER

Perform 100 kHz to 2.6 GHz CW powermeasurements over an 80 dB dynamic range while a built-in calibrator automati- cally performs background calibration.

Specifications:
POWER METERFrequency Range 100 kHz to 2.6 GHzPower Range-60 to +20 dBmDisplay ResolutionSelectable log mode 1, 0.1, 0.01, 0.001 dB Selectable lin mode 2, 3, 4, or 5 significant digitsACCURACYSystem linearity±0.04 dB over a 70 dB rangeCalibration factor uncertainty±3.5% for all frequenciesSensor Module VSWR<1.2:1 Zero Set (digital set zero)50 pw Noise<200 pwZero drift<±200 pW during 20 minutesTemp. coefficient of linearity0.3%/°C Calibrator frequency100 kHz, nominalCalibrator 0.0 dBm uncertainty1.2%Sensor(RF module) Calibrationautomatic, background RF module customer replaceableDamage leve+23 dBmFREQUENCY COUNTERFrequency Range100 kHz to 2.6 GHz (3 auto ranges)100 kHz to 70 MHz, low range, typical50 MHz to 560 MHz, mid range, typical450 MHz to 2.6 GHz, high range, typicalDisplay Resolution1 Hz, low; 10 Hz, mid; 100 Hz, high; 1 sec gateMeasurement Res.1 Hz, low; 8 Hz, mid; 32 Hz, high; 1 sec gateInput Range 0 dBm, (-5 dBm typical) to +20 dBmDamage Level +23 dBmTimebase StabilityStandardTemperature: ±2.5 ppm, 0 to 55°CAging: ±1 ppm per yearHigh Stability OptionTemperature: ±1.0 ppm, 0 to 55°CAging: ±1 ppm per yearAccuracy ±1 LSB ± timebase frequencyGENERAL SPECIFICATIONSApprovals CE mark Temperature rangeOperating: 0 to 55°C (+32 to 131°F)Storage: -40 to 70°C (-40 to 158°F) (excluding batteries)Remote Interface RS 232Battery life 8 hours, typical, power mode8 hours, typical, low frequency4 hours, typical, mid frequency3-1/2 hours, typical, high frequencyType NiMH Overview: Micronetics' Hand-Held PowerMeter combines a power meter and frequency counter with lab grade accuracy in a portable package. Perform 100 kHz to 2.6 GHzCW power measurements over an 80

dB dynamicrange while a built-in cali- brator automatically per- forms background calibra- tion. And the meter also includes a 100 kHz to 2.6 GHz frequency counter. The sensor module is in the meter, and it can bereplaced in a lab or in the field in less than a minute. Measurement data can be downloaded to a PC using the RS 232 serial interface. The light weight, compact size and battery life of upto 8-hours makes Micronetics Hand-Held Power Meter ideal for field test as well as bench top use. FEATURES AND OPTIONS:

FEATURES:¨ CW power measurements over an 80 dB dynamic range,from -60 to +20 dBm ¨ 0.25 dB instrumentation plus calibration accuracy ¨ 100 kHz calibrator automatically performs backgroundcalibration¨ 100 kHz to 2.6 GHz frequency counter with 0 dBm sensi-tivity, -5 dBm typical ¨ Reference oscillator stability is +2.5 ppm, 0 to 55° C, 1 ppm per year standard ¨ High stability oscillator option of 1.0 ppm, 0 to 55° C, 1.0 ppm per year ¨ Weighs less than 2 pounds¨ Measures 3.75" (W) x 8.50" (H) x 1.75" (D) ¨ Battery life of up to 8-hours ACCESSORIESANDOPTIONS:¨ RS-232 Cable ¨ AA Battery Holder ¨ Soft Carrying Case ¨ Spare RF Front End Module¨ NiMh Battery Pack ¨ RF Calibration Cable ¨ High Stability Time Base¨ AC Charger and Power Cable
MICRONETICS/26 HAMPSHIRE DRIVE/ HUDSON, NH 03051 / TEL: 603-883-2900 / FAX: 603-882-8987 WEB: WWW.MICRONETICS.COM

pageCatalog pdf di En 2012-05-22-31