Catalog excerpts
Feature • Range: -100kPa~2.5kPa...200kPa • Gauge • Applicable for non-corrosive gas • I2C signal output, wide temperature range compensation Application • For medical fields, such as electronic sphygmomanometer, respirator, oxygen generator, monitor instrument etc. • For automotive electronics fields, such as tire gauge, EPS, brake booster, MAP sensor etc. • For sports and fitness equipment fields, such as massager, Massage chair, Air bed etc. • For other fields, such as Water heater, oxygen water machine, beer machine, coffee machine, air pump, vacuum pump, pressure meter, electric breast pump, vacuum cleaner etc. Introduction MPM7867 pressure sensor adopts the DIP package. A pressure sensor in SOP package and a signal processing chip are mounted on sides of the PCB. The sensor drift, sensitivity, temperature drift and linearity are digitally compensated through the chip, referring to the supply voltage, it gives a standard digital signal after calibration and temperature compensation. MPM7867 pressure sensor has a compact design and is easy for installation. It can be widely used in medical electronics, automotive electronics, sports and fitness equipment, etc. Specification Power Supply:(5±0.25)V DC Reference Temperature: 25°C http://www.microsensor.cn Add: No.18, Yingda Road Baoji, P.R. China, 721006 MICRO SENSOR CO.,LTD
Open the catalog to page 1http://www.microsensor.cn Add: No.18, Yingda Road Baoji, P.R. China, 721006 MICRO SENSOR CO.,LTD
Open the catalog to page 2Within the I2C procedure, unique situations arise which are defined as START(S)and STOP(P)conditions. When the SCL is HIGH, a HIGH to LOW transition on SDA line indicates a START condition. Data Transfers follow the format shown below. Master device sends the address(7 bits) and the data direction bit R/W of the Slaver in sequence. The addressed slaver will generate an acknowledge and pull down the SDA line in 9th period. After receiving the acknowledge of Slaver, Master shall continue to send 8 bits register address, and start another transfer or read the data after receiving an...
Open the catalog to page 3MPM7867 Pressure Sensor (V1.0) • Correlation between Sensor output and AD value Sensor output after calibration can be seen as actual pressure value(±1.5%Span) Note 1: Output after sensor calibration; Unit: Pa; Note 2: AD value: AD range read from the procedure(-8388608~8388607); Note 3: Sensor range: pressure difference of Up and Low limit, e.g. -100*103~200*103Pa, Full scale=Up limit -Low limit=[200- (-100) ]x103=300*103Pa, has the same unit as that of calibrated sensor output. Code Output Signal Code Accuracy Notes 1. Please make sure the measured media shall be compatible with...
Open the catalog to page 4All Micro Sensor Co. catalogs and technical brochures
-
MPM4700 Level Transmitter
5 Pages
-
MPM380 pressure transducer
3 Pages
-
MPM483 pressure transmitter
6 Pages
-
MPM480 pressure transmitter
6 Pages
-
MS-H375 Hand Communicator
2 Pages
-
tri-valve
2 Pages
-
MPM285 Pressure Sensor
4 Pages
-
MPM286 Pressure Sensor
4 Pages
-
MPM161 PressureSensor
4 Pages
-
MPM162 Pressure Sensor
3 Pages
-
MPM489WZ1
3 Pages
-
MPM489WZ4 Level Transmitter
3 Pages
-
MPM7847 Pressure Sensor
3 Pages
-
MPM7848 Pressure Sensor
3 Pages
-
MPM7858 Pressure Sensor
3 Pages
-
MPM7868 Pressure Sensor
3 Pages
-
MPM7878 Digital Pressure Sensor
29 Pages
-
MPM7888 Digital Pressure Sensor
25 Pages
-
Temperature Switch MTM5881
4 Pages
-
MPM4889 Pressure Transmitter
3 Pages
-
MPM8320 Pressure Transmitter
3 Pages
-
MPM4809TD Level Transmitter
6 Pages
-
MPM4893 Pressure Transmitter
2 Pages
-
MPM4893W Level Transmitter
2 Pages
-
MPM4511 Pressure Transmitter
3 Pages
-
WZP(K) Temperature Sensor
3 Pages
-
M1500 Air Sampling Pump
2 Pages
-
MTM5581 Temperature Switch
4 Pages
-
MPM416W/WK/WRK
7 Pages
-
MPM6861G
4 Pages
-
M1500
2 Pages
-
MFK5081 Flow Switch
4 Pages
-
MFM500 Flow Switch
4 Pages
-
MFE600
24 Pages
-
MPM160 Pressure Sensor
5 Pages
-
mpm426ws level transmitter
3 Pages
-
MPM287 Pressure Sensor
3 Pages
-
MPM288 Pressure Sensor
3 Pages
-
MPM281VC pressure sensor
3 Pages
-
MFM500A Flow Switch
4 Pages
-
MPM484C
3 Pages
-
MS—H375 Hand Communicator
2 Pages
-
MPM4811 Level Transmitter
3 Pages
-
MPM460 MPM460 Pre
5 Pages
-
MPM380 MPM380 Pre
3 Pages
-
MPM4760 MPM4760 Di
4 Pages
-
MFM500 MFM500 Flo
4 Pages
-
LB800 LB800 Seri
3 Pages
-
1151 1151 Tri-v
2 Pages
-
PD140 PD140 Ligh
2 Pages
-
Pressure Switch MPM/MDM580
5 Pages
-
Pressure Switch MPM583
3 Pages
-
Pressure Switch MPM582
3 Pages
-
Pressure Switch MPM5581
7 Pages
-
Flow Switch
4 Pages
-
Appendix LB800
3 Pages
-
Appendix 1151
2 Pages
-
Appendix Cut-off Valve
1 Pages
-
Appendix MS-H376
2 Pages
-
Appendix MS-H376
2 Pages
-
Appendix PD140
2 Pages
-
Appendix MS200
1 Pages
-
OEM Pressure Sensor MPM281
4 Pages
-
OEM Pressure Sensor MPM280
6 Pages
Archived catalogs
-
mdm3051s_DP
13 Pages
-
MPM5881 Pressure Switch
5 Pages
-
MDM3051S -GP-AP
12 Pages
-
MDM3051S -DGP-DAP
10 Pages
-
MPM489B
3 Pages
-
MPM4891 Pressure Transmitter
2 Pages
-
MPM4780 Pressure Transmitter
4 Pages