Measurement Controller MSB9438
5Pages

{{requestButtons}}

Catalog excerpts

Measurement Controller MSB9438 - 1

MSB9438 Multi-screen Pressure/Level Displayer MSB9438 Multi-screen Pressure/Level Displayer Features ·Max.connect two transmitters and display max.3 values; ·Max.processing 3 informations 2 transmitters, 1 difference value, display 3 informations, and output isolated signal 4~20mADC or 0/1~5VDC; ·Set upper and lower limit for max.3 displayed information; ·Two communication interface, RS232/CAN remote or RS485/CAN application; ·Special remote communication interface can complete long-distance data transmitting; ·Max.display range -1999~999999, valid display range -19999999; ·Basic point value set freely basic point: displayed value at transmitter zero or height above sea level; ·No power adjustment available; ·Easy installation, plate or desk installation;。 Introduction MSB9438 pressure/level displayer could receive 2 standard input signals, display information on 3 screens; the 3rd screen displays the difference between values on 1st and 2nd screen, and output 3 standard signals. The product is used for petroleum, electricity and water, city fold prevent and control, especially pressure/level measure, display, control and signal output of water and electricity, chemi-industry, and industry control fields, etc. Specifications Transmitter types: pressure, level and differential pressure transmitter with standard output Transmitter power supply: 24VDC, 300mA Input sensitivity: 1μA / character or 0.1mV / character Zero stability: ±0.4μA ± 0.005% zero maladjustment current/K Inner resolution: 24 bits Display range: Non-linearity error: Display height: http: //www.microsensor.cn Add: No.18,Yingda Road Baoji,P.R.China, 721006 Tel: +86 917 3600739/3600832

Open the catalog to page 1
Measurement Controller MSB9438 - 2

MSB9438 Multi-screen Pressure/Level Displayer Digital display: Display definition: 1st is status bit, 2nd is signal bit, last 6 bits are measuring values Display intensity: Optional long-distance communication digital interface: max.communication distance is 4000m Power supply: Environment temp: Outline Construction and Hole Dimension Unit: mm 465 452 +0.5 0 Outline Construction and Hole Dimension M S B 9 4 3 8 Multi-screen pressure/level displayer Wiring Terminal Chart Communication terminal 3rdsc e control ren U pper Limit K11 U pper Limit K12 K13 K14 Low er Limit K15 Power and...

Open the catalog to page 2
Measurement Controller MSB9438 - 3

MSB9438 Multi-screen Pressure/Level Displayer power(-) Electric connection for 2-wire current input Electric connection for 3-wire vlotage/current input Electric connection for current signal output Electric connection for voltage signal output Application for oil information measure in the tank Electronic Housing R S2 32 R S4 85 MSB9438 Multi-screen Pressure/Levle Displayer http: //www.microsensor.cn Add: No.18,Yingda Road Baoji,P.R.China, 721006 Tel: +86 917 3600739/3600832 Application Example Electronic Housing

Open the catalog to page 3
Measurement Controller MSB9438 - 4

MSB9438 Multi-screen Pressure/Level Displayer Application for water information measure Local place 4-20mA signal Local control room Multi-screen Pressure/Levle Displayer Multi-screen Pressure/Levle Displayer digital signal available for 1st Level Control room Multi-screen Pressure/Level Displayer Code CAN long-distance communication interfacesingle CAN long-distance communication interface RS232 CAN long-distance communication interface RS485 Code Input signal Current input: X= any number in 02, means 02 channel current http: //www.microsensor.cn Add: No.18,Yingda Road Baoji,P.R.China,...

Open the catalog to page 4
Measurement Controller MSB9438 - 5

MSB9438 Multi-screen Pressure/Level Displayer Voltage input: X=any number in 02, means 02 channel voltage XF Output signal and channels The default is no signal output (no code) X=any number in 13: 13 current signal 420mA X=any number in 13: 13 voltage signal 05V X=any number in 13: 13 voltage signal 15V Code Optional control output N=any number 03, 03 control output Please note input, output signal and relative control channel in the order; Communication Instruction”; http: //www.microsensor.cn Add: No.18,Yingda Road Baoji,P.R.China, 721006 Tel: +86 917 3600739/3600832

Open the catalog to page 5