You may also be interested in
Test set, Pyrometer, Position sensor, Eddy current sensor, Inspection machine
Text version of the page
29
Model ILD 1810-50 ILD 2210-10 ILD 2210-20
Measuring range 50mm 10mm 20mm
Start of measuring range 550mm 95mm 90mm
Midrange 575mm 100mm
End of measuring range 600mm 105mm 110mm
Linearity
50ėm 3ėm 6ėm
0.1% FSO 0.03% FSO
Resolution dynamic 1)
5ėm 0.5ėm 1ėm
0.01% FSO 0.005% FSO
Measuring rate 2.5kHz 10kHz
Permissable ambient light 10.000lx 30.000lx
Spot diameter
SMR 400 x 500ėm 130ėm 200ėm
MMR 400 x 500ėm 60ėm 60ėm
EMR 400 x 500ėm 130ėm 200ėm
Light source semiconductor laser <1mW, 670nm (red)
Laser safety class class 2 acc. DIN EN 60825-1 : 2001-11 / Class 2 (IEC 60825-1) Class II (FDA)
Protection class sensor: IP 65 controller: IP 50
Temperature stability 0.01 % FSO/°C
Operation temperature 0 ... 50°C
Storage temperature -20 ... 70°C
Output
analogue ą5V (-10V ... +10V)
digital option: RS232 or RS422 RS422 / 687.5kBaud
Power supply 24VDC (ą15%), max. 500mA
Sensor cable length standard: 2m - integrated option: 5m/10m on request
Controller
functions: auto zero / signal averaging
dimensions: 143mm x 145mm x 52mm - without mounting clips
Electromagnetic compatibility (EMC) EN 50081-1 and EN 50082-2
Vibration 2g / 20 ... 500Hz
Shock 15g / 6ms / 3 axis
Weight
sensor ~800g ~500g
controller ~1000g
FSO = Full Scale Output
All specifications apply for a diffusely reflecting matt white ceramic target
1) series 1810: at 2.5 kHz without averaging, series 2210: at 10 kHz without averaging
SMR = Start of measuring range MMR = Midrange EMR = End of measuring range
Custom Sensor Modifications
For applications where the above standard sensors do not
meet your requirements, it may be possible to supply a
sensor with modified specification. Please contact us for
further information.
Options
- Non standard measuring range and stand off
- Custom housing or mounting geometry
- Measuring rate 2.5 / 5 / 10 / 20kHz
- Non standard signal interfaces
- Special cable length of electrical connector
- Vacuum suitability
- Reduced mass
- Increased shock and vibration resistance
|
|