TABLE OF CONTENTS
USE........................1
MEASUREMENT PRINCIPLE..........3
INSTALLATION..................4
Central unit..................4
Wiring.....................5
Radiation protection..............5
Probe.....................5
ELECTRICAL CONNECTION..........6
Description..................6
Signals to the probe..............6
Connection diagram for
Central unit and Probe............7
Translation chart MG-4000//MG-4000-R2. . 8
INITIALIZE OPERATION.............9
FUNCTIONS ..................10
Measurementvalues.............10
O2-content.................10
Nernst ...................10
Current&Voltage .............10
Temperature................10
Output signals ................10
Relays....................11
Communication ...............11
PROGRAMMING................12
LCDdisplay.................12
Keypad...................12
Startmenu..................12
Theindicationofparameters........12
Programmingaparameter..........12
Programmemenu.............12
Parameterselection............12
Programmingavalue ...........13
Cancelling programming mode ......13
Thefunctionmenu..............13
Defaultsettings ...............14
Communication...............14
Defaultsettings ...............14
Factory...................14
INDICATIONS..................15
Displays...................15
LEDs.....................15
Measuring .................15
Out of range ................15
Calibration.................15
Relay1...................15
Relay2...................15
High O2-content..............15
Low O2-content...............15
Error ....................15
Measurementvalues.............15
Status ....................15
PROBECALIBRATION.............16
MAINTENANCE.................17
Fuses.....................17
TROUBLESHOOTING.............18
Notextdisplayed..............18
The Out of range LED flashes .......18
The Out of range LED is lit.........18
TheHighO2-contentLEDislit.......18
The Low O2-contentLEDislit.......18
MG-4000-R2 shows incorrect O2-content . 18
MG-4000-R2 cannot be calibrated.....18
Errorindications..............18
TECHNICAL DATA...............19
Central unit MG-4000-R2 ..........19
Measuring probe MG-4000-R2/S ......19
LISTOFPARAMETERS............20