MF-PD MicaFlex Microcontroller-based Differential pressure transmitter with digital indication - Micatrone AB - #1 |
|
You may also be interested in
Flow-meter, Differential pressure transmitter, Sensor, Measuring machine, Actuator
Text version of the page
MF-PD
md-1323gb / 2008-10-21
Application
MF-PD is a pressure transmitter designed for
measuring of low positive, negative and differential
pressure.
Output signal in Volt and mA
Simple One-Key zero-setting
Two selectable measuring ranges, full
range or half range
Selectable damping
Calibration certificate attached
Negative or Positive indication of
pressure
Pressure connections
Pressure connections should be made with
Micatrone mounting kits for safe and tight function.
Connect the measurement outputs with HT-plastic
tube 8/6 mm.
Display unit
MF-PD is fitted with a 4-digit LED display and minus
[-] sign when indicating negative pressure.
Zero adjustment
Press down the "zero-setting"-button until the LED
turns off. Release the button and the zero-setting
is finished.
Output signal setting
The Volt/mA-output signal has different terminals.
Check that the correct output is connected.
Setting of damping
The MF-PD offers a possibility to set different
damping (time constant). At delivery the damping
is set to 1,50 seconds damping.
Half measuring range
Through a miniature switch the measuring range
can be set to full range (100%) or to half measuring
range (50%).
NOTE! The accuracy is always for the full range.
Adjusting the measuring range
The measuring range can be adjusted to correct a
measuring deviation. Instruction can be found on
our web site, www.micatrone.se.
Programming
Micaflex PD is programmable with 4 keys on the
display unit and include programmable parameters
for the alarm function and negative indication.
Alarm function
MF-PD include a visual alarm indicated by a
flashing display on alarm state if this function is
activated. By using an optional plug-in module, a
potential-free changing relay output can be obtained.
Alarm can be set for High or Low pressure.
A time delay can be set for 0...600 seconds.
© AB MICATRONE 2008-10-21 [h: \ appdok \ typeset \ datablad \ md-1323gb_081021.vp]
MicaFlex Microcontroller-based Differential
pressure transmitter with digital indication
catrone®
Product data sheet
TG1
T2 LED1
R40
J1
PL1
IC8
C5
R39
K2
INC
DIL1
AC7A
C14
R8
R35
J2
R12
C12
IC6
IC3
AC3
C10
C23
R17
R38
ZERO
IC1
R33
R14
PL2
R34
IC2
R42
DEC
C9
R41
R15
VDR1
R24
K1
R44
R16
K3
D1
C4
R2
K4
R46
IC7
AC9 R37
R11
D2
R32
R21
R31
R7
R47
R23
IC9
T1
AC1
R10
C7
R19
C3
C1
C6
R1
R43
C15
C11
T3
C16
R9
R13
R29
R6
R20
R4
D3
AC8
R25
R45
R30
RGND
C17
IC4
R27
R26
R28
C13
R36
R22
R48
C20
IC5
AC2
C22
R5
C24
D5
C19
D7
C21
R18
D6
C18
C8
C2
D4
AC7D
FM1
FM2 FM3
TEST
(-)
2 3 4
Out
mA
G0
(+)
G0 RANGE
1
G
(-)
DIL1 5
Out
V
ZERO
*
5 DAMPING
DAMPING
see cover
4
3 OUTPUT
*
AB Micatrone
P3778 v3.01
Top Silk
2
1
R110
D103
DIG4
IC101
RP101
H2
R101
LED101 LED102
R112
D101
LED103
C101
C102
SW4
SW3
SW2
SW1
R109
R111
RP102
D104 D102
LED105
D105
J101
R102
H1
FM2
FM3
K101
DIG1 DIG2 DIG3
LED104
SNAP1
FM1
AB Micatrone
P3761
Top Silk
PGM ESC
8 8 8 8
Zero-setting button
miniature switch
Adjustment keys .