Catalogue IC Column
www.metrohm.com
print switch display
Page / 164
Contact the
Manufacturer
Where to buy
this product ?
Request
a Quote
Metrohm - 4475
/ 164
See other catalogues for Metrohm
Text version of the page
IC anion separation columns for analyses with or without chemical suppression

Metrosep A Supp 4 – 250 (6.1006.430)

The Metrosep A Supp 4 is an extremely robustcolumn with very good separation properties. The separation phase consists of polyvinyl alcohol particles with a diameter of 9 µm, which are functionalized with quaternary ammonium groups. This arrangement guarantees a high stability and great tolerance to very fine particles that could pass through the built- in filter plate. The Metrosep A Supp 4 has a medium ion exchange capacity; sulfate elutes after 12.5 min. The number of plates that can be achieved with this column is higher than with the Metrosep Dual 2 separation column. For 5 mg/L chloride and 10 mg/L sulfate, 5900 respectively 5800 theoretical plates have been determined. Metrosep A Supp 4 is parti- cularly suitable for all routine tasks in water analysis. Its universal applicability makes it into the standard column for the Compact Metrohm IC Systems 792 Basic IC, 761 Compact IC and 861 Advanced Compact IC. Technical information Carrier materialPolyvinyl alcohol with quaternaryammonium groupsColumn dimensions250 x 4.0 mm Column bodyPEEK Standard flow1.0 mL/min Maximum flow2.0 mL/min Maximum pressure12 MPa Particle size9 µm Organic modifier0...100% pH range3...12 Temperature range20...60 °C Capacity71 µmol (Cl Applications • standard anions • water analysis • method development • difficult matrices • critical samples • iodide
) Eluents Without chemical suppression Phthalic acid eluentPhthalic acid1660 mg/2 L5.0 mmol/L (standard eluent)Acetone40 mL/2 L2.0%TRISpH = 4.4With chemical suppressionCarbonate eluent Sodium hydrogen carbonate286 mg/2 L1.7 mmol/L (standard eluent)Sodium carbonate382 mg/2 L 1.8 mmol/LCarbonate eluent, mod. 1Sodium hydrogen carbonate336 mg/2 L2.0 mmol/LSodium carbonate509 mg/2 L 2.4 mmol/L Acetone100 mL/2 L5.0%Carbonate eluent, mod. 2Sodium hydrogen carbonate168 mg/2 L1.0 mmol/L Sodium carbonate848 mg/2 L 4.0 mmol/L Ordering information 6.1006.430Metrosep A Supp 4 6.1006.500Metrosep A Supp 4/5 Guard 6.1006.540Metrosep A Supp 4/5 S Guard To protect the IC column – even though it is notparticularly sensitive – we recommend the use of the Metrosep A Supp 4/5 Guard column (6.1006.500). If the column oven is used then Metrosep A Supp 4/5 S Guard column (6.1006.540) must be used. 50
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
151-164
pdf-page pdf di En 2008-11-47-23