Catalogue Electrical Installations Safety
www.metrel.si
print switch display
Page / 28
METREL - 40090, 14776
/ 28
See other catalogues for METREL
Text version of the page

6

Strong reasons to ACT now!

Revolutionary

AUTO SEQUENCE

®

testing and certifying safety of low voltage electrical installations

The main benefits of the new

AUTO SEQUENCE

®

testing are:

• Save time and speed-up operator's work: up to 5 times faster testing than with manual procedures. • Immediate verification: delivering automatic evaluation of safety with pass/fail indication for each performed test and overall test results simultanously. • Make test operation simple and comprehensible: one single press of the TEST button for all the necessary operations. EurotestAT guides the operator through whole procedure. • Take the troubles out of report creation: EurotestAT PC software gives you all the necessary tools to generate standardized test report in less than a minute. • Increase reliability: up to 50 acquired test results with corresponding parameters are saved at once. Preprogrammed test sequences guarantee that none of necessary tests will be forgotten ever. • Safe usage: automatically detects possible safety hazards for the operator, by means of continuous monitoring of terminal voltages and by PE touch industrial electrode TEST key, which are active in all test functions.

PC SOFTWARE-Lite

Using EurotestAT and Euro Link PC Software for certifying installations and providing measurement reports . Memory tree structure can contain 2000 locations with 10 levels in depth.A name can be assigned to each location. The name can later be changed.narbitaryStored results at each location can later be recalled or

Ordering information

Standard Set Part No. MI 3101

deleted. After the results are transferred to a PC standard test reports can be prepared with little or no modification of instrument data/results. The test report is prepared in a less than a minute. All the results are displayed under the corresponding location of the structure, including test parameters, limits and PASS/FAIL

- Instrument EurotestAT- Plug commander 1,5 m- Test cable Universal connection 3 x 1,5 m - Test tips, 3 pcs (blue, black, green)- Aligator clips, 3 pcs (blue, black, green)- Power supply adapter + 6 NiMH AA batteries- Soft carrying neck belt- Soft carrying bag- PC SW

Communication interface

Example of a created standard test report

EuroLink - Lite- RS 232/PS cable- USB cable- Instruction manual on CD- Instruction manual short- Handbook “Measurement in practice” on CD- Product verification data

EurotestAT comes with USB and RS 232 ports as standard.

Optional Accessories A 1012A 1192A 1191A 1197 A 1198S 2026S 2027

information.

A 1160A 1110A 1111 A 1169 A 1202A 1201

Eurolink enables printing of the installation structure.

A 1196
Contact voltage U
C Operation:typical 13 hCharger socket input voltage: 12 V A 1012 - Probe test lead 4 m Measuring range:0 V
:: : ¸ 100 V
: ; Acc (-0 % / +15 %)U ÷ 10 VCharger socket input current:400 mA max.Battery charging current:250 mA (internally regulated)Overvoltage category:600 V CAT III for instrument 300 V CAT III for A 1110 - Three phase cable
C lim : 25 V (50 V) A 1111 - Three phase adapter Tripping time A 1143 - Euro-Z 290 A impedance adapter (see page 18) non-delayed (time-delayed) RCDs: A 1160 - Fast 6 cells AA Charger with a set of 6 pcs NiMH teries ´ 1: 0 ms ¸ 300 ms (500 ms) plug commanderProtection classification:double insulationPollution degree:2Protection degree:IP 40Display:320 x 240 dots matrix display with backlightDimensions ´ 2: 0 ms ¸ 150 ms (200 ms) A 1169 - Fast 12 cell C, AA Charger ´ 5: 0 ms ¸ 40 ms (150 ms), UC: 0.0 V ¸ 99.9 VAccuracy: 0 A 1191 - Receiver R10K ¸ 40 ms ±1 ms; 0 ¸ 999 ms ±3 ms A 1192 - Special selective probe Tripping current I
D : 0.2 ´ I
D N ¸ 1.1 ´ I
D N AC ( ¸ 1.5 ´ I
D N A) ± 0.1×I
D N A 1196 - PC SW Euro Link - PRO t
D : 0 ms ¸ 300 ms, UC: 0.0 V
:: : ¸ 100.0 V
: A 1197 - Tip Commander 1.5 m, 3 W Multiplier: ´ 0.5, ´ 1, ´ 2, ´ 5 A 1198 - Magnetic contact probe Resistance to earth (EN 61557-5) (w x h x d):23 cm x 10,3 cm x 11,5 cmWeight:1,32 kg without batteryes A 1199 - r adapter for 4W soil resistivity (see page 18) Measuring range: 0,00 W ¸ 199 W ±(3 % + 3 D); 200 W ¸ 9999 W Working temperature range: 0C
OO A 1201 - Insulated sticks for testing on LV at a distance Open-circuit voltage: < 45 V
RMS ¸ 40 CLocator supports inductive mode operating voltage up to: 440 VRS 232:115200 baudUSB:256000 baud A 1202 - Additional extension part for A 1201 Short-circuit current:< 20 mA S 2026 - Earth 20 m set 3 W General S 2027 - Earth 50 m set 3 W Power supply voltage:9 V
DC (6 x 1.5 V batteryes, size AA) CS 2099 - Eurocheck bat

7

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7