Each model performs all safety tests and meets all the requirements of reference standards for testing of the following parameters: Extra added advanced features and many strong unique solutions and troubleshooting tools, especially designed by Metrel:
LPEN Three-Phase rotation Voltage and Frequency monitor. Continuity +/- 200 resistance test.Loop/earth resistance
230<10 230 Big graphic LCD with warnings, instructions and easy to read icons.PE touch industrial electrode on TEST button. mA. Insulation (50V, 100V), 250 V,
?
with two clamps. Help with connection circuits on the instrument’s screen. Leakage current TRMS. Medical environment IMD and ISFL test for IT earthing systems. LUX sensor.
TN/T T/IT TN / TT / IT earthing system support. 500 V, 1000 V. Line / Loop impedances with RCD trip-lock function and Ipsc calculationRCD tripping time Voltage system recognizing – 110 V, 230 V, 400 V, reduced 55V and 63 V . Real time and date added to each result.
IT
IMD PC SW, memory, USB and RS232 data transfer and tripping current. Contact voltage and Earth resistance calculation. PASS / FAIL evaluation of all the results. Earth
OFF Long life battery operation. Auto OFF function.
RCD AUTO >
Instrument Type
Comparison table
SINGLE FUNCTION TESTS >
Measurement functions and other
EurotestXA EurotestAT EurotestXE EurotestEASI
Part No.: MI 3105 MI 3101MI 3102 MI 3100
Voltage Monitor/ TRMS >
/ / /
.
/
.
PHASE SEQUENCE EN 61557-7 CONTINUITY EN 61557-4 Automatic polarity exchange, 200mA Low current continuous 7 mA DCResistance test through shuko N-PE INSULATION - IEC/ EN 61557-2 50 / 100 / 250 / 500 / 1000 VAutomatic test between L-N-PE pairs Adjusting test time to object Capacitance 50 ... 1000 V50 ... 1000 V100 ... 1000 V100 ... 1000 V Medical sites - IT RMD test, ISFL LINE/LOOP EN 61557-3 Ipsc, U L-N-PE, freq u encyImpedance L-N and L-PEImpedance L-LR and Xl calculationsHigh accuracy RCD TRIP LOCK loop impedanceIT system line/loopIT system first fault loop Built-in Fuse base characteristics PASS/FAIL evaluation of result RCD EN 61557-6 RCD typeRCD AUTOTESTTrip-out time t, Uc(I >
D N )Trip-out current I >
D A, AC, BA, ACA, ACA, AC EARTH EN 61557-5 Two wire earth resistanceThree wire earth resistanceHigh noise immunity Two clamps earth/loop resistanceOne clamp earth/loop resistance Specific Earth resistanceOptionalyOptionaly CURRENT CLAMP TRMS Clamp leakage current >
AUTO SEQUENCE ® Automatic test of RCD >
AUTO SEQUENCE ® on SwitchBoard >
AUTO SEQUENCE ® on Circuit Automatic evaluation of complete safetyAutomatic test of insulation ALL L-N-PE Preparing results for verification reports Smart commands, comments, icons, instructions, ... SENSOR Lux OptionalyOptionaly OTHER Line Tracer OptionalyOptionaly Touch electrode Evaluation PASS/FAIL results FrequencyVoltage systems support Reduced low voltage system support Earthing system support 15 - 500 Hz15 - 500 Hz45 - 65 Hz45 - 65 Hz440 / 230 / 110 V440 / 230 / 110 V440 / 230 / 110 V440 / 230 / 110 V55 / 65 V55 / 65 V55 / 65 V55 / 65 VTN / TT / ITTN / TT / ITTN / TT / ITTN / TT / IT ON LINE WARNINGS HELP menus COMMUNICATION PORTS RS 232 USB ACCESSORIES Plug commander Tip commander 2 wire Tip commander 3 wireOptionalyOptionlayPC SoftwareProfessional PROProfessional LITEStandardQuerty keypad on screen >