Catalogue Electrical Installations Safety
www.metrel.si
print switch display
Page / 28
Make a request   
METREL - 14776, 14568
/ 28
See other catalogues for METREL
Text version of the page

Each model performs all safety tests and meets all the requirements of reference standards for testing of the following parameters: Extra added advanced features and many strong unique solutions and troubleshooting tools, especially designed by Metrel:

LPEN
Three-Phase rotation Voltage and Frequency monitor. Continuity +/- 200 resistance test.Loop/earth resistance
230<10 230
Big graphic LCD with warnings, instructions and easy to read icons.PE touch industrial electrode on TEST button. mA. Insulation (50V, 100V), 250 V,

?

with two clamps. Help with connection circuits on the instrument’s screen. Leakage current TRMS. Medical environment IMD and ISFL test for IT earthing systems. LUX sensor.
TN/T T/IT
TN / TT / IT earthing system support. 500 V, 1000 V. Line / Loop impedances with RCD trip-lock function and Ipsc calculationRCD tripping time Voltage system recognizing – 110 V, 230 V, 400 V, reduced 55V and 63 V . Real time and date added to each result.

IT

IMD
PC SW, memory, USB and RS232 data transfer and tripping current. Contact voltage and Earth resistance calculation. PASS / FAIL evaluation of all the results. Earth
OFF
Long life battery operation. Auto OFF function.
RCD AUTO
Industrial fuse / fault Locator.

Instrument Type

Comparison table

SINGLE FUNCTION TESTS

Measurement functions and other

EurotestXA EurotestAT EurotestXE EurotestEASI

Part No.: MI 3105 MI 3101MI 3102 MI 3100
Voltage Monitor/ TRMS

/ / /

.

/

.
PHASE SEQUENCE EN 61557-7 CONTINUITY EN 61557-4 Automatic polarity exchange, 200mA Low current continuous 7 mA DCResistance test through shuko N-PE INSULATION - IEC/ EN 61557-2 50 / 100 / 250 / 500 / 1000 VAutomatic test between L-N-PE pairs Adjusting test time to object Capacitance 50 ... 1000 V50 ... 1000 V100 ... 1000 V100 ... 1000 V Medical sites - IT RMD test, ISFL LINE/LOOP EN 61557-3 Ipsc, U L-N-PE, freq u encyImpedance L-N and L-PEImpedance L-LR and Xl calculationsHigh accuracy RCD TRIP LOCK loop impedanceIT system line/loopIT system first fault loop Built-in Fuse base characteristics PASS/FAIL evaluation of result RCD EN 61557-6 RCD typeRCD AUTOTESTTrip-out time t, Uc(I
D N )Trip-out current I
D A, AC, BA, ACA, ACA, AC EARTH EN 61557-5 Two wire earth resistanceThree wire earth resistanceHigh noise immunity Two clamps earth/loop resistanceOne clamp earth/loop resistance Specific Earth resistanceOptionalyOptionaly CURRENT CLAMP TRMS Clamp leakage current
AUTO SEQUENCE ® Automatic test of RCD
AUTO SEQUENCE ® on SwitchBoard
AUTO SEQUENCE ® on Circuit Automatic evaluation of complete safetyAutomatic test of insulation ALL L-N-PE Preparing results for verification reports Smart commands, comments, icons, instructions, ... SENSOR Lux OptionalyOptionaly OTHER Line Tracer OptionalyOptionaly Touch electrode Evaluation PASS/FAIL results FrequencyVoltage systems support Reduced low voltage system support Earthing system support 15 - 500 Hz15 - 500 Hz45 - 65 Hz45 - 65 Hz440 / 230 / 110 V440 / 230 / 110 V440 / 230 / 110 V440 / 230 / 110 V55 / 65 V55 / 65 V55 / 65 V55 / 65 VTN / TT / ITTN / TT / ITTN / TT / ITTN / TT / IT ON LINE WARNINGS HELP menus COMMUNICATION PORTS RS 232 USB ACCESSORIES Plug commander Tip commander 2 wire Tip commander 3 wireOptionalyOptionlayPC SoftwareProfessional PROProfessional LITEStandardQuerty keypad on screen

3

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
pdf-page pdf di En 2008-10-41-07