Demonstration Boards

Demonstration board MI 3099Demonstration board MI 2166Demonstration board MA 2067

Fault simulator for education purpose on low-voltage electrical installations in compliance with standards: VDE 0100, BS 7671, CEi 64.8,HD 384• Simulation of common electrical installation usually met in individual house or apartment. This board is to be used preferably by sales personnel when demonstrating operation of electrical installation test equipment. Demonstration board MI 3099 represents detailed installation structure with important elements on Switchboard and on Circuit side, supporting one and three phase system. Excellent tool for training and education, schools and laboratories.• Complete representation of a real low voltage installation in industrial and residential areas. The board includes all typical elements found The TN-C(S) or TT type of earthing system on electrical installation with or without RCD could be simulated where the loads could be switched on or off. This • Various test methods supported by different test instruments can be presented.• Acceptable or faulty board is to be used for presentation of complete initial and periodic testing of safety on any electrical installation. The difference between existing way of testing and testing according new patent pending in real systems: sockets, electrical loads, lightning and earthing systems for TT, TN and IT types of installations.• • Fault situation simulation switches can generate 19 errors or those combination.• Detailed instruction manual with profound explanation of all typical measurements. centers65 different measurements according to IEC/EN61557 are supported. parameters can be preset by five »fault« switches. • Some real elements of electrical installation are revolutionized AUTO SEQUENCE solution could be expressed. • This board is to be used preferably by sales personnel when demonstrating operation of electrical installation test equipment.
® placed on the front panel like RCD protection device, ON/OFF switch with lamp, mains test outlet and connection terminals. • Various AUTO SEQUENCE test procedures supported for demonstration of testing safety on Switchboard and on one phase / three phase Outlets by new EurotestXA and EurotestAT.• Different test instruments can be presented, using allmethods.• Connection to real three phase or only to single phase system possibility.• protected against
® dangerous contact voltage. standardized Electronically

Standard Set Part No. MA 2067 Standard Set Part No. MI 2166Standard Set Part No. MI 3099

- Demonstration board MA 2067- Jumper, 4 pcs- Demonstration board support (for vertical use)- Single phase matching cable (code no. 20 691 648)- Instruction manual MI 2166- Jumper, 2 psc- Mains cable- Instruction manual - Demonstration board MI 3099- Jumper- Special tip, 3 psc- Mains cable- Three phase to one phase adapter- Instruction manual- Demonstration board

Technical Specification

Mains connection:three-phase type 3P+N+PE or over three-phase type 3P+N+PE or over single-phase matching cable, 2 msingle-phase matching cable, 2 msingle-phase matching cable, 2 mDimensions:680 x 175 x 450 mm (w x h x l)490 x 140 x 460 mm (w x h x l) 490 x 140 x 460 mm (w x h x l) Mass:12.5 kg3.45 kg5 kgStandards: EN 61010-1 (safety)EN 61010-1 (safety)EN 61010-1 (safety)EN 50081-1 (EMC)EN 50081-1 (EMC) EN 50081-1 (EMC)EN 50081-1 (EMC) EN 50081-1 (EMC) EN 50081-1 (EMC)Pollution degree:222Over current category:CAT II 300 VCAT II 300 VCAT II 300 VProtection class:I (with protective conductor)I (with protective conductor)I (with protective conductor)

27

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
pdf-page pdf di En 2008-10-41-07