Catalogue Electrical Installations Safety
www.metrel.si
print switch display
Page / 28
METREL - 162597, 4415
/ 28
See other catalogues for METREL
Text version of the page

calibrator intended for use with installation test instruments. Function and accuracy of all Metrel and most other manufacturer's installation test instruments can be verified with Eurocheck. Regular tests with Eurocheck will reveal doubts about results that may look correct, but in fact they are wrong due to the instrument malfunction. Features

Ordering information

• Insulation function calibration.• Continuity function calibration.• Fault loop impedance calibration with RCD trip-lock function .• Calibration of RCD trip-out time measurement.• Line impedance calibration.• Voltage and frequency calibration.• Measurement leads verification.• PE test terminal functional verification.• Automatic mains polarity verification. Eurocheck is a professional, multifunctional field

Standard set Part. No. CS 2099
- Instrument Eurocheck- Soft carrying bag- Instruction manual - Declaration of warranty

Eurocheck

Comparison table

Instrument Type

Earth-Insulation tester Eurotest

MI 2088MI 2088-20MI 2088-50 MI 2086 EUMI 2086 ST

Instaltest Installcheck

Measurement functions and other

Part No.: MI 2087 MI 2150

INSULATION Insulation Resistance Test voltage 50 V/100 V/250 V/1000 V DC
500 V
Continuity of PE Conductors Automatic polarity exchange, Test current >200 mA CONTINUITY Low Resistance Continuous measurementNo polarity exchange, Low test current
Z
LINE / I
PCS ; L-L, L-N Loop Impedance Z / I
LOOP PCS ; L-PE Contact voltage at I
PCS ; Auxililary test rod method Line Resistance
LINE, LOOP RCD (FI)
R
LINE / I
PCS ; L-N Loop Resistance R
LOOP / I
PCS ; L-PE Loop Resistance L-PE; Without tripping RCD, Test current 15 mA ; (Without tripping the RCD) Earth-Loop resistance ; (Without tripping the RCD) Earth Resistance Test current I
D N /2 (Without tripping the RCD), Auxililary test rod method RCD Trip Out Time ; Test current 0.5I
D N , I
D N , 5I
D N I D N RCD Trip Out Current (Ramp test) RCD Automatic Test Line Impedance Total Earth Resistance ; Test method with four /three / two test rods

// //

Particular Earth Resistance ; Test method with two test rods and one clamp
EARTH
Earth Resistance ; Test method with two clamps Specific Earth resistance ; Test method with four test leads / four test rods Voltage and Current Harmonics
POWER,HARMONICS
(W, VA, Var, cos j ) Energy (Wh)
SENSOROTHER
Illumination Frequency PC SoftwareIEC / EN 61557Installation Tracing Varistor Breakdown Voltage Ramp test voltage 50 up to 1000 V DC; 500 V/sTreshold current 1mA Mains VoltagePower Voltage Logging Current 0,2 mA up to 200 A; Clamp measurement - True RMS PE Terminal Test (presence of phase voltage) Analysis of mains Outlet (Wiring) Phase Rotation Contact voltage (Faults, Fuses, Wires) Plug Commander (Start, Stop, Store)
ACCESSORIES
Tip Commander (Start, Stop, Store)
STANDARD 1, 2, 3, 4, 5, 6, 7

1, 2, 3, 4, 6, 7

1, 2, 4, 5

7

19

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28