Electrical installations safety

Earth-Insulation tester

Ultimate Instruments for Testing Earth and Insulation Resistance

• Multifunction, digital measuring instrument for testing of earthing and lighting protection systems, PE conductor continuity testing and DC insulation resistance measurement on low voltage electrical installations in accordance with IEC/EN 61557. • • • 30 G Measurements on earthing and lightning protection systems include: standard 4-wire method, standard 4-wire method with current clamps and 2-clamp method without junctions disassembling.Specific earth resistance (soil resistance).DC insulation resistance measurement with test voltages from 50 V up to 1000 V in 10 V steps. Measuring range up toOther features: mains voltage and frequency measurement, clamp current measurement, varistor testing.Internal memory with a capability to store up to 1000 test results that can later be transferred W . • • • to a personal computer.Software package EarthLink compatible with MS Windows operation systems allows download of test results from the instrument to a personal computer. Measurements and testing in accordance with: DIN / VDE 0100; BS 7671, 16th Edition; CEI 64.8; HD 384; EN / IEC 61557; DIN / VDE 0413; EN / IEC 61010-1; EN 50081-1; EN 50082-1

OFF

SINGLE FUNCTION TESTS

Measurements per each set Earth-Insulation set 20 mEarth-Insulation set 50 Insulation set

Technical Specification

Insulation Resistance Accuracy:±(3 % + 3 D)Short-circuit test current:<7 mA Display range Riso (Un Å‚ 250 V): 0 – 000 M W ÷ 29.9 G W Display range Riso (Un < 250 V): 0 – 000 M W ÷ 199.9 M W Earth Resistance (four-lead method) Resolution:0.001; 0.01; 0.1; 1; 10; 100 M W Display range:0 ÷ 19.99 k W Accuracy:±(2 % + 2 D)… (0¸199.9 M W )Nominal test voltage:50 Resolution:0.01; 0.1; 1; 10 W ÷ 1000 V in steps of 10 VGenerator current capability:>1 mA at Unom.Display range (test voltage): 0 Basic accuracy:±(2 % + 3 D)… (0 ÷ 2 k W )Test voltage:<40 V / 125 Hz / sine waveShort-circuit test current:<20 mAHigh noise rejection: yesAut. potential and current probe res. test:yes ÷ 1200 V Continuity of Protection Conductors (single measurement)Display range:0.00 ÷ 19.99 20.0 ÷ 199.9 200 ÷ 1999 W Accuracy:±(2 % + 2 D)±(3 %) Test current:>200 mACompensation of test leads (up to 5 Earth Resistance (four-lead method + clamp) + A1018 Display range: 0 ÷ 1.99 k W W ):yesAutomatic polarity exchange:yes Other characteristics see under four-lead methodEarth Resistance (two test clamps) : A1018+A1019 Continuity (continuous measurement)Display range:0.0 Display range:0 ÷ 19.99 W 20.0 ÷ 100.0 W ÷ 199.9 W 200 ÷ 1999 W Basic accuracy:±(10 % + 2 D) ±(20 %)

16

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
pdf-page pdf di En 2008-10-41-07