Brochure Climate Chambers
34Pages

{{requestButtons}}

Catalog excerpts

Brochure Climate Chambers - 6

Climate chambers CONSTANT CLIMATE CHAMBERS HPPeco CONSTANT CLIMATE CHAMBERS HPPeco according to DIN 12880:2007-05, EN 61010-1 (IEC 61010-1), EN 61010-2-010 Stainless steel, mat. 1.4301 (ASTM 304), deepdrawn Standard units are safety-approved and bear the test marks: Textured stainless steel, rear zinc-plated steel, intuitively operated TwinDISPLAY (TFT colour display) with touchscreen Double doors: Outside stainless steel, fully insulated, inside glass (size 1400/2200 stainless steel doors with glass sector, fully heated inner glass panes integrated in the full-sight glass door with 2-point...

Open the catalog to page 6
Brochure Climate Chambers - 7

Climate chambers Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) includes replacement of standard grids by reinforced grids (standard with 1060) Light module cold white 6,500 K: LED light strips arranged on the side walls of the interior, 10 for model 110, 14 for model 260/410/750, programme controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature and humidity; not in combination with F6, F7, D8 Light module cold white 6,500 K + warm...

Open the catalog to page 7
Brochure Climate Chambers - 8

Climate chambers CONSTANT CLIMATE CHAMBERS HPPeco Holder for water tank (sizes 110 - 750: 2.5 litres, sizes 1060/1400/2200: 10 litres) for mounting on the rear of the appliance. Standard equipment for sizes 410, 750, 1060, 1400 and 2200 Central water supply with filter cartridges for connection to the domestic water supply. Product information on demand Central water supply without filter cartridges for connection to the domestic water supply (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7). Product information on demand Guarantee extension by...

Open the catalog to page 8
Brochure Climate Chambers - 12

Climate chambers HUMIDITY CHAMBERS HCP according to DIN 12880:2007-05 , EN 61010-1 (IEC 61010-1), EN 61010-2-010 Stainless steel, material 1.4301 (ASTM 304), deepdrawn, seamlessly welded Standard units are safety-approved and bear the test marks: Textured stainless steel, rear zinc-plated steel, intuitively operated TwinDISPLAY (TFT colour display) with touchscreen; fully insulated stainless steel door and heated inner glass door Mains cable with plug (German type) Model sizes/Description Stainless steel interior Textured stainless steel exterior Standard equipment Volume Width Height Depth...

Open the catalog to page 12
Brochure Climate Chambers - 13

Climate chambers Voltage 115 V, 50/60 Hz Battery-buffered ControlCOCKPIT: uninterrupted supply for the entire display unit (ControlCOCKPIT) and therefore complete documentation of all parameters even when there is a power failure Entry port, 23 mm clear diameter, at the side left centre/top right centre/top 4 - 20 mA current loop interface Temperature controller, actual value (0 to +100 °C = 4 - 20 mA) Humidity controller, actual value (0 to 100 % rh = 4 - 20 mA) Works calibration certificate for one (freely selectable) temperature and humidity value according to customer specification...

Open the catalog to page 13
Brochure Climate Chambers - 16

Climate chambers CLIMATE CHAMBERS ICHeco CLIMATE CHAMBERS ICHeco according to DIN 12880:2007-05, EN 61010-1 (IEC 61010-1), EN 61010-2-010 Stainless steel, mat. 1.4301 (ASTM 304), deepdrawn Standard units are safety-approved and bear the test marks: Textured stainless steel, rear zinc-plated steel, intuitively operated TwinDISPLAY (TFT colour display) with touchscreen Double doors: Outside stainless steel, fully insulated, inside glass (size 750: two leaves) Connection: Mains cable with plug (German type) Mounted on lockable castors Model sizes/Description Stainless steel interior Volume...

Open the catalog to page 16
Brochure Climate Chambers - 17

Climate chambers Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) - includes replacement of standard grids by reinforced grids (ICHeco/ICH and ICH C only) Illumination unit (has to be ordered together with the second box chamber) consisting of 4 fluorescent lights with cold white light (daylight: light colour 865, 6,500 K) and 2 UV lamps in the spectral range of 320 to 400 nm, acc. ICH Q1B, option 2 (daylight and UV light comply with standard illuminant D65) separately switchable...

Open the catalog to page 17
Brochure Climate Chambers - 18

Climate chambers CLIMATE CHAMBERS ICHeco IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer IQ/OQ document with device-specific works test data for one free-selectable temperature value, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05. PQ check list as support for validation by customer. 305 € for further temperature values IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, incl. temperature distribution survey at Memmert for 27 measuring...

Open the catalog to page 18
Brochure Climate Chambers - 19

Climate chambers CLIMATE CHAMBERS ICH according to DIN 12880:2007-05, EN 61010-1 (IEC 61010-1), EN 61010-2-010 Stainless steel, mat. 1.4301 (ASTM 304), deepdrawn Standard units are safety-approved and bear the test marks: Textured stainless steel, rear zinc-plated steel, intuitively operated TwinDISPLAY (TFT colour display) with touchscreen Double doors: Outside stainless steel, fully insulated, inside glass (size 750: two leaves) Connection: Mains cable with plug (German type) Mounted on lockable castors Model sizes/Description Stainless steel interior Volume Width Height Depth (less 33 mm...

Open the catalog to page 19
Brochure Climate Chambers - 20

Climate chambers Model sizes/Description Packing data Order No. Climate Chambers ICH = Climate chamber ICH L = Climate chamber with light ICH C = Climate chamber with CO2 control Options Voltage 115 V, 50/60 Hz Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) - includes replacement of standard grids by reinforced grids (ICHeco/ICH and ICH C only) second box Illumination unit (has to be ordered together with the chamber) consisting of 4 fluorescent lights with cold white light...

Open the catalog to page 20
Brochure Climate Chambers - 21

Climate chambers Accessories Central water supply without filter cartridges for connection to the domestic water supply (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7). Product information on demand CO2 pressure reducing valve to DIN 8546, incl. gas cylinder monitor (only ICH C) USB-Ethernet adapter Ethernet connection cable 5 m for computer interface USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering...

Open the catalog to page 21

All Memmert GmbH + Co. KG catalogs and technical brochures

  1. Steriliser S

    2 Pages

  2. Incubator I

    2 Pages

  3. ServicePlus