| | | | | | | | | | | | | | | Sensor | M5/2 | M5/4 | M5/10 | M5/20 | M5/100 | M5/200 | | | | Range [mm] | 2 | 4 | 10 | 20 | 100 | 200 | | | | Range begin [mm] | 23 | 22 | 40 | 55 | 170 | 240 | | | | Linearity* ± [mm] | 0,004 | 0,008 | 0,02 | 0,04 | 0,2 | 0,4 | | | | Resolution* [mm] | 0,0005 | 0,001 | 0,003 | 0,006 | 0,03 | 0,06 | | | | Light spot diameter [mm] | 0,8 | 0,8 | | | | | | | | | | | | | | | | | | |
| | | Light source Sampling frequency | | LED, infrared 890 nm - invisible 2,5 kHz ±10V; optional: ±5V/0...10V/4...20mA/RS232/RS485 approx. 0 Ohm (10 mA max.) with 30° of inclination (A-axis): approx. 0,5% on white surface 1 ms, 2 ms or 20 ms adjustable 500 Hz, 200 Hz or 20 Hz (-3 dB) 0,02% ofrange/K 0 ... 10 V +24V/10 mAwhen lowerthan MIN, LED yellow +24V/10 mAwhen higherthan MIN and lowerthan MAX, LEDgreen +24 V/10mA when higher than MAX, LED orange Relay output 0,5A/100V for "MIN", "OK" and "MAX" approx. 0,5% of range +24 V/10 mA when not enough light, LED yellow +24 V/10 mA when too much light, mirroring surface , LED red 20.000 Lux 50.000 h for LED 200 VDC, 0V against case 5gupto1 kHz (sensor head, 20 g optional) 0° ... +70°C -20° ... +70°C bis 90% RH Sensor: IP 64, Electronic system: IP 40 +24 VDC/200 mA(10 ... 30 V) | | |
| | | Delivery: •Sensor with connection cable 2m •Electronic unit •25 pin D-connector for soldered joint •Calibration report | | Options: •Special cable length •Cable output on the right side •Sensor head with integrated protection window •Sensor head vibration resistant •Sychronisation of2 sensors | | Accessories: •Protection casing •RS 232-Interface •RS 485-Interface •Extension cable 2m/3m •Power supply •Plug-on powersupply •Digital display (display in mm) •More accessories on request | | |