Text version of the page
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | --J Sensor | M9L/ | M9L/ | M9L/ | M9L/ | M9L/ | M9L/ | M9L/ | | | | | 2 | 10 | 20 | 50 | 100 | 200 | 500 | | | | Range [mm] | 2 | 10 | 20 | 50 | 100 | 200 | 500 | | | | Range begin [mm] | 24 | 30 | 40 | 45 | 70 | 70 | 200 | | | | Linearity* [mm] | 0,002 | 0,008 | 0,015 | 0,04 | 0,08 | 0,2 | 0,4 | | | | Resolution* [mm] | 0,0002 | 0,002 | 0,004 | 0,01 | 0,02 | 0,04 | 0,05 | | | | Light spot diameter [mm] | 0,2 | 0,4 | 0,3 | 0,5 | 0,6 | 1,2 | 1,5 | | | | | | | | | | | | | | | | | | | | | | | Light source Laser, 670 nm, red visible Laser protection class 2 Distance output ±5 V / optional RS 232 Angle error with 30° of inclination (A-axis): approx. 0,5% on white surface Reactiontime 1,5 ms Bandwith 5 kHz (-3 dB) Temperature drift 0,01% of range / K | | | | | | Analog outputs | | | | | | 3 ms 2,5 kHz | | | | | | | | | | | | | | | | | | Switching output | | | | | | not enough light 30V/100 mA optical coupler | | | | | | | | | | | | | | Ambient light Operation time Isolation voltage max. Vibration Operation temperature Storage temperature Humidity Protection class Supply | | 10.000 Lux 50.000 h for Laser diode 200 VDC, 0V against case 5gupto1 kHz 0° ... +50°C -20° ... +70°C 5 - 95% RH Sensor IP 65, Controller IP 50 21 ... 27 VDC < 500 mA | | | | | | | | | | | | | | * Measurement on object colorwhite | | | | | | | | | | Delivery: •Sensor with connection cable 2 m •Controller •25pin D-connector, soldering version •Calibration report | | | | | | 3 | | | | | | Synchronisation by connected controllers | | | | | | | | | | | | | | AB A | | | | | | | | | | | | | | t3 | | | | | | | | | | Accessories: •Cable extension •Protection casing | | | | | | Controller for all types of sensors Weight 1000g | | | | | | If the sensors are mounted too close, the ambient light ofa close-by sensor can influence the measurement result Synchronisation is standard. The controllers have to be wired together. | | | | | | | | | | | | | | Options: •RS 232-Interface | | | | | | | | | | 154 | | | | | | | | | | | | | | LO cm" | | | | | | | | | | 3^5 | | | | | | 100 | | | | | | | | | | | | | | 173 | | | | | | | | | | DB-M9_1-00-E | | | | | | | | | | MIKROELEKTRONIK GmbH • Tel. +49 89/327150-0 • Fax +49 89/319 20 23 • www.MELsensor.de | | | | | | | | | | -31- | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|