Catalogue KAT-komplett-Optische-Sensoren_1-00-E
www.melsensor.de
print switch display
Page / 42
MEL Mikroelektronik - 2096, 2490
/ 42
See other catalogues for MEL Mikroelektronik
Text version of the page
For special surfaces like solder
Sensor
M72L/
M72L/
M72L/
0,5
2
4
Range [mm]
0,5
2
4
Range begin [mm]
23,75
23
22
Linearity* ± [mm]
0,001
0,004
0,008
Resolution* [mm]
0,0001
0,0005
0,001
Light spot diameter [mm]
0,1
0,2
0,3
Light source
Laser, 670 nm, red visible
Sampling frequency
54 kHz
±10V(optional 0 ... 10V/0...5V/±5V) RS232/4...20 mA (optional 0...20mA) approx. 0 Ohm (10 mA max.)
with 30° of inclination (A-axis): approx. 0,5% on white surface
0,1 ... 67 ms
0,015 ... 10 kHz (-3dB)
0,02% ofrange/K
0 ... 10 V
+24V/10 mAwhen lowerthan MIN, LED yellow
+24V/10 mAwhen higherthan MIN and lowerthan MAX, LED green
+24 V/10mA when higher than MAX, LED orange
+24V/10 mA, LED red
approx. 0,5% of range
20.000 Lux
50.000 h for Laser diode
200 VDC, 0V against case
5gupto1 kHz (sensor head, 20 g optional)
0° ... +50°C
-20° ... +70°C
up to 90% RH
Sensor: IP 64, Electonic system: IP 40 +24 VDC/200 mA(10 ... 30 V)
Distance output
Impedance Angle error Reaction time Bandwith Temperature drift Intensity output
Analog Outputs
MIN OK MAX Error output
Switching outputs
Switching hysteresis Ambient light Operation time Isolation voltage max. Vibration Operation temperature Storage temperature Humidity Protection class Supply
*Measurementonobjectcolorwhite - bandwith15Hz
Delivery:
•Sensor with connection cable 2m •Electronic unit
•25 pin D-connector, soldering version •Calibration report
Options:
•Special cable length •Sensor head with integrated protection window
•Sensor head vibration resistant
Accessories:
•Thickness-measuring system •Increases laser capacity •Protection casing •Interference filter •RS 232- Interface •Extension cable 2m •Power supply •Plug-on powersupply •Digital display (display in mm) •More accessories on request
Special types on request
DB-M72J-00-E
IÎ\ÂlIÊ!1Lî MIKROELEKTRONIK GmbH • Tel. +49 89/327150-0 • Fax +49 89/319 20 23 • www.MELsensor.de
-22-
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42