| | | Technical Data M2DW/50 Hz- and110 Hz version: | | |
| | | |
| | | | | | | | | | | | | Scanner | M2DW-75/30 | | M2DW-160/40 | M2DW-120/100 | | | | Case type | 9 | | 10 | 7 | | | | Range Z [mm] | 75 | | 160 | 120 | | | | Begin scan range X [mm] | 30 | | 40 | 100 | | | | End scan range X [mm] | 40 | | 110 | 100 | | | | Range begin [mm] | 90 | | 44,6 | 47 | | | | Resolution Z [mm] | 0,15 | | 0,25 | 0,3 | | | | Resolution X [mm] | 0,05 | | 0,16 | 0,3 | | | | Laser protection class | | | 2 | 2 | | | | | | | | | | | | |
| | | |
| | | Scan rate* Shutter speed** Specials | | |
| | | 50 Hz 110 Hz 1/4000 s up to 1/125 s 1/47.000 up to 1/225 s feeler gage, elapsed hour counter serial number electronically readable Connections for air- or water-cooling Laser, wave length 658 nm, red visible 5.000 Lux Laser diode: 50.000 h 5gupto1 kHz 0°... +40°C -20° ... +70°C < 90% RH IP64 via Electronic module: i-Control, Blue Box or ISA-Card white to black, shiny, high mirroring | | |
| | | |
| | | Light source Abient light Operating time max. Vibration Operating temperature Storage temperature Humidity Protection class Power supply Measuring surface | | |
| | | |
| | | *) please order **) adjustable via software | | |
| | | |
| | | Lieferumfang: • Sensor head • Sensor cablel 2 m • Demo-Software | | Optionen: • Special cable length | | Zubehör: • Protection window / glass • Protection window / plastics • 2 Scanner synchronized | | |
| | | |
| | | |
| | | • Manual • Electronic module alternativ: - i-Control - Blue Box -ISA-Card | | |
| | | |
| | | DB-M2DWJ-00-E | | |
| | | |
| | | JIx/i[lÈkI£ì MIKROELEKTRONIK GmbH • Tel. +49 89/327150-0 • Fax +49 89/319 20 23 • www.MELsensor.de -10- | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | |