You may also be interested in
Permanent magnet, Magnet, Contactor, Switch, Reed relay
Text version of the page
BE Series MEDER electronicAll PurposeReed RelaysRELAY DATAAll Date at 20° CSwitch Model → Contact Form Switch 66 Form A / BSwitch 85 Form AContact RatingsConditionsMin.Typ.Max.Min.Typ.Max.Units →Switching Power *Any DC combination of V & A not to exceed their individual max.‘s 10100WSwitching VoltageDC or peak AC2001000VSwitching CurrentDC or peak AC0.51.0A Carry CurrentDC or peak AC1.252.5A Static Contact Resistancew/ 0.5 V & 10 mA150150mΩDynamic Contact Resis-tanceMeasured w/ 0.5 V & 50 mA , 1.5 ms after closure200200mΩInsulation Resistance (100 Volts applied)Across contacts Contact to coil10 10 10 10 12 10 12 12 ΩBreakdown VoltageAcross contacts Contact to coil225 2.0 *4000 2.0 VDC kVDC Operate Time incl. BounceMeasured w/ 100 % overdrive0.51.0 msReset Time Measured w/ no coil suppression 0.10.1msCapacitanceAcross contacts Contact to coil 0.2 5.00.2 5.0pF Life Expectancies 6 Switching 5V & 10 mADC only & <10 pF stray cap.100050010 Cycles For other load requirements, see the life test section on P. 121. Environmental Data Shock Resistance1/2 Sine wave duration 11ms5050gVibration Resistance10 - 2000 Hz2020gAmbient Temperature10°C/minute max. allowable-2070-2070°C Storage Temperature10°C/minute max. allowable-40105-40105°C Soldering Temperature5 sec. dwell260260°C * 4.5 kVDC / 3.0 kVRMS when the V option is selected. www.meder.com120 |
|