| | | KSK-1A55-... | | |
| | | MEDER electronic | | |
| | | |
| | | |
| | | DIMENSIONS All dimensions In mm [Inches] | | CHARACTERISTICS Glass length of 16.5 mm and diameter of 2.8 mm Normally open 1 Form A contact Inrush current up to 3 A Excellent for lamp loads High power up to 50 W switching | | |
| | | |
| | | [0.650] | | |
| | | |
| | | -Œ | | |
| | | |
| | | [0.864] | | |
| | | |
| | | |
| | | [1.728] | | |
| | | |
| | | | | | | | | | | | | | All Data at 20 oC | Switch Model — Contact Form — | KSK-1A55-... Form A | | | | | Contact Ratings | Conditions | Min. | Typ. | Max. | Units | | | | Switching Power* | Any DC combination of V and A not to exceed their individual max.'s | | | 50 | W | | | | Switching Voltage | DC or peak AC | | | 200 | V | | | | Switching Current | DC or peak AC | | | 0.5 | A | | | | Carry Current | DC or peak AC | | | 3.0 | A | | | | Static Contact Resistance | at 0.5 V & 10 mA | | | 150 | mQ | | | | Dynamic Contact Resistance | measured w/ 0.5 V & 50 mA, 1.5 ms after closure | | | 200 | mQ | | | | Insulation Resistance cross Contacts | 100 Volts applied | 10= | | | Q | | | | Breakdown Voltage | > 60 sec. | 250 | | | VDC | | | | Release Time incl. Bounce | 100 % overdrive | | | 1.0 | ms | | | | Release Time | measured with/ no coil suppression | | | 0.1 | ms | | | | Capacitance | at 10 kHz across contact | | 0.2 | | PF | | | | Test Coil ** | | | KMS-01 | | | | | Standard AT range | | 20 | | 70 | AT | | | | Environmental Data | | | | | | | | | Shock Resistance | 1/2 sine wave for 11 ms | | | 50 | g | | | | Vibration Resistance | 10 - 2000 Hz | | | 20 | g | | | | Ambient Temperature | max. 10 oC / minute allowance | -20 | | 130 | oC | | | | Stock Temperature | max. 10 oC / minute allowance | -55 | | 130 | oC | | | | Soldering Temperature | 5 sec. dwell | | | 260 | oC | | | | | | | | | | | | | |
| | | CONTACT DATA | | |
| | | |
| | | |
| | | Note: The indicated electric data are maximum values can vary downwards when using a more sensitive switch. * For life expectancy see our test section on Page 112. ** See our test section on Page 116. | | |
| | | |
| | ORDER INFORMATION | | |
| | | |
| | | | | | | | | | | | Series | Contact Form | Switch Model | At Range (between) | | | | KSK - | 1A | 55 - | xxxx | | | | Options | | | 20 -70 | | | | | | | | | | | |
| | | Part Number Example - KSK - 1A55 - 2025 | | |
| | | |
| | | 2025 is the AT range (Any AT can be ordered between 20 & 70 in a minimum range of 5 AT) | | |
| | | |
| | | |
| | | www.meder.com | | |
| | | |