PPT-080 & PPT-110
5Pages

{{requestButtons}}

Catalog excerpts

PPT-080 & PPT-110 - 1

Proximity Probes TransducerPPT-080 & PPT-110 FEATURES • Non-contacting measurement system based on eddy current principle • Designed for long life cycles and harsh environments • Custom rugged cable jacket preventing breaking and tearing of the probe cable • High resistance to corrosive environments • Certified for use in potentially explosive atmospheres • 5m and 9m systems • Measuring ranges, 2mm or 4mm • Loop powered transmitter (4-20mA) Monitoring solution Axial thrust position Shaft relative vibration Typical applications yf J Hydrogenator's _D Pumps, fan, cooling towers. Gas & steam turbines The Proximity Probe Transducer (PPT) is used for non-contact measurements of shaft vibration and position. Each system consists of a probe (PPS), an extension cable (PPE) and a signal conditioner (PPC). The PPT series proximity probe systems are designed to meet API 670 standard recommendation. The voltage output is directly proportional to the measured distance between the metallic target and the sensor face. Probe and extension cable : Designed for long life cycles and suitable for harsh environments, probe and extension cables are equipped with armor and protective rubber boots, which cover the connectors and prevent oil and dirt penetration. Extension cable is compliant with API670 standard, allowing compatibility with other manufacturers' proximity probe systems. Driver (conditioner) : Used with related probe and extension cable. The circuit is isolated from ground. The total length of cable between the probe and the driver is either 5 m or 9 m.

Open the catalog to page 1
PPT-080 & PPT-110 - 2

GLOBAL SPECIFICATIONS OPERATION Linearity (deviation from straight line) if calibrated as system including interchangeability errors Frequency response (±3dB) Minimum target size Maximum load (PPC-081 4..20 output) Power Transducer version Linear range Sensitivity Temperature sensitivity (-30°C to 120°C) PPT-080 0.25mm to 2.25mm 7.87mV/|jm ±0.3%/°C (middle of the linear range) Current consumption (static) < 12mA ENVIRONMENTAL Temperature range Sensor & cable Operation/Storage -40° to +120°C Operation Storage Sensor dimensions [mm] PPS-080 70 L x 08 terminated by 1m1 cable 08 Driver...

Open the catalog to page 2
PPT-080 & PPT-110 - 3

GLOBAL SPECIFICATIONS HAZARDOUS AREA ATEX II 1 G,Ex ia IIC T4 Ga@Ta=-55°C to +115°C EN60079-0:2012,EN60079-11:2012,EN60079-26:2007 IECEx:Ex ia IIC T4 Ga IECEx DEK 13.0037 X IEC 60079-0:2011,Ed.6 IEC 60079-11:2011,Ed.6 IEC 60079-26:2006,Ed.2 TR CU: 0Ex ia IIC T4 Ga X N° TC RU C-US. AA87.B.01245 NANIO CCVE rOCT 31610.0-2014 (IEC 60079-0:2011) rOCT 31610.11-2014 (IEC 60079-11:2011) PROBE DRIVER APPROVAL ATEX II i g, Ex ia IIC T4 Ga@Ta=-40 oC to +80 oC IECEx IECEx DEK 13.0020 X CSA Intrinsically safe Class l, Div. 1, Gr. A, B, C and D,T4 Class l, Zone 0, Ex ia llC T4 Class 1, Div. 2, Gr. A, B,...

Open the catalog to page 3
PPT-080 & PPT-110 - 4

Sensor type Unthreaded length Case length Total Length Connector PPS-080 07 M10x1 No armor XX Increment: 01 YY Increment: 01 05 0.5m 02 With connector *Default configuration Armor 00 Without armor 110 Sensor type PPC- 080 8mm probe PPC- 110 11mm probe Total system length Hazardous Area Certification 50 5.0m 00 No Mounting 00 DIN rail 01 Plate mount *Default configuration 4..20mA output driver - PPC-081 Probe and cable (not included) Mount Approval

Open the catalog to page 4
PPT-080 & PPT-110 - 5

MECHANICAL DRAWING PPC driver PPS-080 (armored version with 9m extension cable) PPS-110 (armored version with 9m extension cable) MC-monitoring Quality certifications LOCAL REPRESENTATIVE V. MC-monitoring SA Route Andre Piller 19 CH-1762 Givisiez | Switzerland Phone : +41 58 411 54 00 Mail : info@mc-monitoring.com

Open the catalog to page 5

All MC-monitoring SA catalogs and technical brochures

  1. PMM-300P Rhino

    10 Pages

  2. PMM-305

    7 Pages

  3. CPP

    4 Pages

  4. RTM-200

    4 Pages

  5. MFT-100

    4 Pages

  6. SPP-201

    3 Pages

  7. RCP-004

    3 Pages

  8. LVS-301

    4 Pages

  9. PAS-138

    3 Pages

  10. FAS M2

    3 Pages

  11. FAS M5

    3 Pages

  12. FAS-200

    3 Pages

  13. AGT-3G

    14 Pages

  14. PPT-120

    3 Pages

  15. PMS-300P Rhino

    13 Pages

  16. SCD-200

    3 Pages

  17. DRS-020

    3 Pages

  18. PMS-391

    3 Pages