Air Gap Transducer - 3G technology AGT-3G Monitoring solution Embedded Digital Signal processing High-speed grade FPGA 6x300 MHz. Active Temperature compensation High accuracy and repeatability. Advanced algorithm for noise rejection Increased immunity to electrical disturbances IN/OUT Galvanic separation. Immunity to strong magnetic field Typical applications Hydrogenerators Gearless millsdrives DESCRIPTION The dynamic air gap monitoring of generators consists of the distance measurement between rotor poles and stator while it is in operation. The MCm AGT range of air gap sensors are a non-contact dynamic position transducer utilising a capacitive technique to provide an accurate displacement measurement from the sensor face to a metal target. The advantage of the capacitive technique in generator applications is the high immunity to magnetic fields; the AGT series also provides high resolution and relative insensitivity to different (metal) target materials. Typical contact-free capacitive Air Gap Transducer (AGT) is composed of 3 elements. It features separate Sensor (AGS), the Air Gap Oscillator (AGO) and the Demodulator (AGD). Demodulator The demodulator provides three signal outputs : 1 • MinGap voltage (V) • Pole Profile voltage (V) 1 • Pole Profile or MinGap current (mA) All outputs are galvanically isolated and the current output is factory set on Pole Profile. The digital technology combined with high performance noise rejection filters allow a linearization adjusted with great accuracy and resolution, with stable and repetitive behaviours. Industrial metal housing enables installation in harsh environments. Sensor and Oscillator Designed for long life cycles, harsh environments and strong magnetic fields. The sensor shape is suitable for its installation on the stator wall of generators and motors. 1 See user manual for detailed description

Open the catalog to page 1
AGT-3G - 2

MEASURING RANGES OVERVIEW

Open the catalog to page 2
AGT-3G - 3

mcmonitoring AGT-212 3G SPECIFICATIONS AGD-212 M4 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error AGD-212 M5 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error AGD-212 M7 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error AGD-212 M8 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average...

Open the catalog to page 3
AGT-3G - 4

TRANSDUCER OVERVIEW

Open the catalog to page 4
AGT-3G - 5

Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error PHYSICAL [mm] Sensor surface 385 x 20 x 3.5 LxWxH Sensor interface MCX coaxial plug Conditioner module dimensions 170 x 63 x 40 LxWxH TRANSDUCER OVERVIEW AirGap Demodulator (AGP) Flexible metal conduit SPR-AS AirGap Oscillator (AGO) AGO grounding wire AGT-3G _Datasheet.pub © MC-monitoring SA / 2024-01-16 / English Page 5

Open the catalog to page 5
AGT-3G - 6

AGT-525 3G SPECIFICATIONS AGD-525 M1 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error AGD-525 M2 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error PHYSICAL [mm] Sensor surface 221 x 32 x 3.5 LxWxH Sensor interface MCX coaxial plug Conditioner module dimensions 170 x 63 x 40 LxWxH TRANSDUCER OVERVIEW AirGap Demodulator (AGP) Flexible metal conduit SPR-AS

Open the catalog to page 6
AGT-3G - 7

AGT-530 3G SPECIFICATIONS AGD-530 M3 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error PHYSICAL [mm] Sensor surface Sensor interface AGO-2xx dimensions Conditioner module dimensions 5 to 30mm (0.2 to 1.18 in) 0.32V/mm 0.64mA/mm < 3.5% of reading from 11mm to 29mm < 5.0% of reading from 5mm to 30mm < 0.8% 221 x 32 x 3.5 LxWxH LEMO triaxial plug (AGS-525 M4) 016x100 170 x 63 x 40 LxWxH

Open the catalog to page 7
AGT-3G - 8

AGD-550 M1 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error AGD-550 M2 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error AGD-550 M3 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error PHYSICAL [mm] Sensor surface Sensor interface Adapter module dimensions Conditioner module dimensions 5 to 50mm (0.2 to 1.96 in) 0.178V/mm 0.355mA/mm < 4.2% of reading...

Open the catalog to page 8
AGT-3G - 9

AGT-550MX 3G SPECIFICATIONS AGD-550 MX Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error PHYSICAL [mm] Sensor surface Sensor interface Adapter module dimensions Conditioner module dimensions 263 x 80 x 3.5 LxWxH MCX coaxial plug 120 L x 025 170 x 63 x 40 LxWxH TRANSDUCER OVERVIEW AirGap Demodulator (AGP) Flexible metal conduit SPR-AS

Open the catalog to page 9
AGT-3G - 10

mcmonitoring AGT 3G HT SPECIFICATIONS (High Temperature applications) AGD-105 M1 Linear measuring range

Open the catalog to page 10
AGT-3G - 11

AGT 3G HT SPECIFICATIONS (High Temperature applications)TRANSDUCER OVERVIEW AirGap Demodulator (AGD1 F exib e meta conduit SPR-AS Flexible metal conduit SPR-AS

Open the catalog to page 11
AGT-3G - 12

OPERATION Output function Output range Loop resistance (current output) Output resistance (voltage outputs) AGD-xxx Mx temperature coefficient AGO-xxx M3 temperature deviation max. Typical frequency response (-3dB) Output noise Interchangeability tolerance Power Voltage Current consumption Sensor (AGS) triaxial cable length AGS-212 M4, M5, M6: AGS-520 M2: AGS-525 M3, M4: AGS-550 M3: AGS-550 MX: ENVIRONMENTAL Temperature range : Operation Temperature range (HT models) : Operation Long term storage (all models) : Ingress protection (acc. to EN60529) Relative humidity (non-condensing) Intended...

Open the catalog to page 12
AGT-3G - 13

ORDERING INFORMATION List Of Parts Numbers: Output range

Open the catalog to page 13
AGT-3G - 14

ORDERING INFORMATION Standardized CoMPREHENSiVE Systems MC-monitoring Quality certifications LOCAL REPRESENTATIVE MC-monitoring SA Route Andre Piller 19 | PO BOX 97 CH-1762 Givisiez | Switzerland Phone : +41 58 411 54 00 Mail : info@mc-monitoring.com

Open the catalog to page 14

All MC-monitoring SA catalogs and technical brochures

  1. PMM-300P Rhino

    10 Pages

  2. PMM-305

    7 Pages

  3. CPP

    4 Pages

  4. RTM-200

    4 Pages

  5. MFT-100

    4 Pages

  6. SPP-201

    3 Pages

  7. RCP-004

    3 Pages

  8. LVS-301

    4 Pages

  9. PAS-138

    3 Pages

  10. FAS M2

    3 Pages

  11. FAS M5

    3 Pages

  12. FAS-200

    3 Pages

  13. PPT-120

    3 Pages

  14. PMS-300P Rhino

    13 Pages

  15. SCD-200

    3 Pages

  16. DRS-020

    3 Pages

  17. PMS-391

    3 Pages