See other catalogues for
MAYR
You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | |
| | | mayr | | |
| | | ROBA®-multiswitch Type 019.100.2 | | |
| | | |
| | | |
| | | Application | | |
| | | C€ | | |
| | | |
| | | ROBA®-multiswitch fast acting rectifiers are used to connect DC units to alternating voltage supplies, for example electromagnetic brakes and clutches (ROBA-stop®, ROBA®-quick, ROBATIC®), electromagnets, electrovalves etc. Fast acting rectifier ROBA®-multiswitch 019.100.2 • Consistently controlled output voltage in the entire input voltage range. • Consumer operation with overexcitation or power reduction • Input voltage: 100 - 500 VAC • Max. output current: 2 A | | |
| | | |
| | | |
| | | ROBA®-multiswitch units are not suitable for all applications, e.g. use of the ROBA®-multiswitch when operating noise-damped brakes is not possible without taking additional measures. The product's suitability should be checked before use. | | |
| | | e | | |
| | | |
| | | |
| | | Function The ROBA®-multiswitch units are (dependent on size) used for an input voltage of between 100 and 500. After switch-on, they emit the rectified bridge voltage for 50 ms and then control the 90 or 180 VDC overexcitation voltages. After the overexcitation period, they control the 52 or 104 VDC holding voltages. The overexcitation period can be adjusted via a DIP-switch to 150 ms, 450 ms, 1 s, 1,5 s and 2 s. | | |
| | | 54 | | |
| | | |
| | | |
| | | 64 | | |
| | | Electrical Connection (Terminals) 1 + 2 Input voltage (fitted protective varistor) 3 + 4 Connection for external contact for DC-side switch-off 5 + 6 Output voltage (fitted protective varistor) | | |
| | | Accessories: Mounting bracket set for 35 mm rail acc. to EN 50022: Article-No. 1802911 | | |
| | | |
| | | col ml | | |
| | | |
| | | |
| | | |
| | | Technical Data | | |
| | | |
| | | | | | | | | | | Input voltage Output voltage | see Table 1 see Table 1 | 9oeoeoeeo€L-— | | | | 1 2 3 4 5 6f™ | | | | Protection | IP65 components, IP20 terminals | | | | | Terminal nom. cross-section | 1,5 mm2, (AWG 22-14) | 69 | | | | Ambient temperature | -25 °C up to +70 °C | | | | | Storage temperature | -40 °C up to +105 °C | | | | | | | | | | | |
| | | |
| | | ROBA®-multiswitch Sizes, Table 1 | | |
| | | |
| | | Size | | |
| | | |
| | | | | | | | | | | | 10 | 20 | | | | Input voltage VAC ± 10 % acc. to EN 50160 | 100 - 275 | 200 - 500 | | | | Frequency input voltage Hz | 50 - 60 | 50 - 60 | | | | Output voltage U ~ a over VDC ± 10 % | 90 | 180 | | | | Output voltage Uho|d VDC ± 10 % ° | 52 | 104 | | | | Output current IRMS at < 45 °C ADC | 2,0 | 2,0 | | | | Output current IRMS at max. 70 °C ADC | 1,0 | 1,0 | | | | Conformity | | | | | | markings | C€ | | | | | | | | | | | |
| | | Order Number / 0 1 | | |
| | | 9.1 0 0.2 | | |
| | | |
| | | Size 10 20 | | |
| | | | | |
| | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |