ROBA®-switch Type 017.110.2
Application
ROBA®-switch fast acting rectifier units are used to connect DC units to alternating voltage supplies, for example electromagnetic brakes and clutches (ROBA-stop®, ROBA®-quick, ROBATIC®), ectromagnets, electrovalves, etc.
Fast acting rectifier ROBA®-switch 017.110.2
• Consumer operation with overexcitation or power reduction
• I ntegrated automatic DC-side disconnection (shorter connection time)
• I nput voltage: 100 - 500 VAC
• Max. output current IRMS : 1,5 A
• UL-approved
E189728 V V
The ROBA®-switch units with integrated automatic DC-side disconnection are not suitable for use as safety disconnections!
Dimensions (mm)
Function
The ROBA®-switch units are used for operation at an input voltage of between 100 and 500 VAC, depending on the size. They can switch automatically internally from bridge rectification out­put voltage to half-wave rectification output voltage. The bridge rectification time can be modified from 0,05 to 2 seconds by exchanging the external resistor (Rext).
The ROBA®-switch units also have an integrated automatic DC-side disconnection. In contrast to the conventional DC-side disconnection, no further protective measures or external components are necessary. The DC-side disconnection is stand­ard-activated (terminals 3 and 4 are not wired), resulting in short electromagnetic consumer switching times.
The integrated automatic DC-side disconnection is deactivated by fitting a bridge between the terminals 3 and 4. The coil is deener-gised via the free wheeling diode. This has the advantages of softer braking and a lower switching noise. However, the switching times increase (taking approx. 6 - 10 times longer).
54
64
Accessories: Mounting bracket set for 35 mm rail acc. to EN 50022: Article-No. 1802911
54
ffi I T. 4,5
15
CO N.
oeoeoeeoeoee
O CM
Electrical Connection (Terminals)
1 + 2 Input voltage (fitted protective varistor)
3 + 4 Switching between DC- and AC-side disconnectio
5 + 6 Output voltage (fitted protective varistor)
7 + 8 Rext for bridge rectifier timing adjustment
1
+ 5 6 7 8
69
Technical Data
Input voltage Output voltage Protection
Terminal nom. cross-section Ambient temperature Storage temperature
ROBA®-switch Sizes, Table 1
Size
10
20
Input voltage
100..
200..
VAC ± 10 %
..250
..500
Output voltage
90..
180..
VDC, Ubndge
..225
..450
Output voltage
45..
90..
VDC, U „
' half-wave
..113
..225
Output current |rms
at < 45 °C, (A)
1,5
1,5
Output current |rms at max. 70 °C, (A)
0,75
0,75
Conformity
cW.
markings
1 C€
see Table 1 see Table 1
IP65 components, IP20 terminals IP10 Rext
1,5 mrm*2, (AWG 22-14) -25 °C up to +70 °C -40 °C up to +105 °C
Order Number
__ / 0 1 A
Size 10 20