See other catalogues for MAYR
You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | mayr | | | | | | Half-wave Rectifiers and Bridge Rectifiers Type 02_.000.6 | | | | | | | | | | | | | | Application | | | | | | | | | | Ì189728 V V | | | | | | Rectifiers are used to connect DC units to alternating voltage supplies, for example electromagnetic brakes and clutches (ROBA-stop®, ROBA-quick®, ROBATIC®), electromagnets, electrovalves, contactors, switch-on safe DC motors, etc. | | | | | | | | | | | | | | Function The AC input voltage (VAC) is rectified (VDC) in order to operate DC voltage units. Also, voltage peaks, which occur when switching off inductive loads and which may cause damage to insulation and contacts, are limited and the contact load reduced. Electrical Connection (Terminals) 1 + 2 Input voltage 3 + 4 Connection for an external switch for DC-side switching 5 + 6 Coil 7 - 10 Free nc terminals (only for size 2) | | | | | | s (mm) | | | | | | | | | | A | | | | | | 19 | | | | | | | | | | | | | | C | | | | | | | | | | | | | | LU | | | | | | | | | | Order Number __ / 0 2 A Size 1 up to 4 | | | | | | .0 0 0.6 | | | | | | | | | | | | | | | | | | | | | Size | A | B | C | 0D | E | | | | 1 | 34 | 30 | 25 | 3,5 | 4,5 | | | | 2 | 54 | 30 | 44 | 4,5 | 5,0 | | | | 3/4 | 64 | 30 | 54 | 4,5 | 5,0 | | | | | | | | | | | | | | | | | A 4 5 | | | | | | Half-wave rectifier Bridge rectifier | | | | | | | | | | | | | | | | | | Accessories: Mounting bracket set for 35 mm rail acc. to EN 50022: Article-No. 1803201 | | | | | | | | | | | | | | | | | | | | | | | | | | Technical Data | Bridge rectifier | | Half-wave rectifier | | | | | Calculation output voltage | VDC = VAC x 0,9 | | VDC = VAC x 0,45 | | | | | Type | 1/025 | 2/025 | 1/024 | 2/024 | 3/024 | 4/024 | | | | Max. input voltage | 230 VAC | 230 VAC | 400 VAC | 400 VAC | 500 VAC | 600 VAC | | | | Max. output voltage | 207 VDC | 207 VDC | 180VDC | 180VDC | 225 VDC | 270 VDC | | | | Output current at < 50°C | 2,5 A | 2,5 A | 3,0 A | 4,0 A | 4,0 A | 4,0 A | | | | Output current at max. 85 °C | 1,7 A | 1,7 A | 1,8 A | 2,4 A | 2,4 A | 2,4 A | | | | Max. coil capacity at 115 VAC < 50 °C | 260 W | 260 W | - | - | - | - | | | | Max. coil capacity at 115 VAC up to 85 °C | 177 W | 177 W | - | - | - | - | | | | Max. coil capacity at 230 VAC < 50 °C | 517 W | 517 W | 312 W | 416 W | 416 W | 416 W | | | | Max. coil capacity at 230 VAC up to 85 °C | 352 W | 352 W | 187 W | 250 W | 250 W | 250 W | | | | Max. coil capacity at 400 VAC < 50 °C | - | - | 540 W | 720 W | 720 W | 720 W | | | | Max. coil capacity at 400 VAC up to 85 °C | - | - | 324 W | 432 W | 432 W | 432 W | | | | Max. coil capacity at 500 VAC < 50 °C | - | - | - | - | 900 W | 900 W | | | | Max. coil capacity at 500 VAC up to 85 °C | - | - | - | - | 540 W | 540 W | | | | Max. coil capacity at 600 VAC < 50 °C | - | - | - | - | - | 1080 W | | | | Max. coil capacity at 600 VAC up to 85 °C | - | - | - | - | - | 648 W | | | | Peak reverse voltage | 1600 V | 1600 V | 2000 V | 1600 V | 2000 V | 2000 V | | | | Rated insulation voltage | 250 Vrms | 320 Vrms | 500 Vrms | 500 Vrms | 630 Vrms | 630 Vrms | | | | Pollution degree (insulation coordination) | 2 | 2 | 2 | 1 | 2 | 2 | | | | Protection fuse | | To be included in the input voltage line. | | | | | Recommended microfuse switching capacity H The microfuse corresponds to the max. possible connection capacity. If fuses are used corresponding to the actual capacities, the permitted limit integral R must be observed on selection. | FF 3,15A | FF 3,15A | rr 4A | nn 5A | FF 5A | FF 5A | | | | Permitted limit integral l2t | 40 A2s | 40 A2s | 50 A2s | 100 A2s | 50 A2s | 50 A2s | | | | Protection | | IP65 components, encapsulated / IP20 terminals | | | | | Terminals | | Cross-section 0,14 - | 1,5 mm2 (AWG 26-14) | | | | | Ambient temperature | | | - 25 °C up to + 85 °C | | | | | | Storage temperature | | | - 25 °C up to + 105 °C | | | | | | Conformity markings | UL, CE | UL, CE | UL, CE | UL, CE | UL, CE | CE | | | | Installation conditions | The installation position can be user-defined. Please ensure sufficient heat dissipation and air convection! Do not install near to sources of intense heat! | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|