DATASHEET 56V MODULE - 5 Pages

Add to MyDirectIndustry favorites
DATASHEET 56V MODULE

Catalog excerpts

DATASHEET 56V MODULE FEATURES AND BENEFITS TYPICAL APPLICATIONS Standard rackmount configurations Up to 10KW in half rack, 4U module UL registered component Datacenter UPS Hospital UPS Industrial Process Equipment Backup Power for graceful shutdown Transition power for motorgenerator set or fuel cells PRODUCT SPECIFICATIONS ELECTRICAL Rated Capacitance BMOD0130 P056 B03 130 F 1 Minimum Capacitance, initial Maximum ESR DC, initial 130 F 1 8.1 mΩ 1 Rated Voltage Absolute Maximum Voltage 56 V 62 V 14 Maximum Continuous Current (ΔT = 15 C) o 61 A 2 Maximum Continuous Current (ΔT = 40oC)2 99 A Maximum Peak Current, 1 second (non repetitive) 1,800 A Standby Current, maximum (Passive Balancing)4 120 mA 3 Maximum Series Voltage 750 V TEMPERATURE Operating Temperature (Ambient temperature) Minimum -40oC Maximum 40oC Storage Temperature (Stored uncharged) Minimum -40oC Maximum 70oC Page 1 Document number: 1017119.2 maxwell.com

 Open the catalog to page 1

DATASHEET 56V MODULE PRODUCT SPECIFICATIONS (Cont’d) PHYSICAL BMOD0130 Mass, typical 18 kg Power Terminals M8/M10 Recommended Torque - Terminal 20/30 Nm Telcordia GR-63-CORE Zone 4 Vibration Specification Shock Specification - Environmental Protection IP30 Cooling Natural Convection MONITORING / CELL VOLTAGE MANAGEMENT Internal Temperature Sensor N/A Temperature Interface N/A Cell Voltage Monitoring Overvoltage Alarm Connector Deutsch DTM Cell Voltage Management Passive POWER & ENERGY Usable Specific Power, Pd5 Impedance Match Specific Power, Pmax 2,600 W/kg 5,400 W/kg 6 Specific Energy,...

 Open the catalog to page 2

DATASHEET 56V MODULE PRODUCT SPECIFICATIONS (Cont’d) BMOD0130 Cycle Life1,9 1,000,000 cycles Capacitance Change 20% ESR Change 100% Test Current 100 A (% decrease from minimum initial value) (% increase from maximum initial value) Shelf Life 1,10 2 years (Stored uncharged up to a maximum storage temperature) SAFETY Short Circuit Current, typical 6,900 A (Current possible with short circuit from rated voltage. Do not use as an operating current.) Factory High-Pot Test13 3,500 V DC RoHS UL810a (750 V) Certifications TYPICAL CHARACTERISTICS THERMAL CHARACTERISTICS Thermal Resistance N/A...

 Open the catalog to page 3

DATASHEET 56V MODULE NOTES 1. Capacitance and ESRDC measured at 25°C per Document Number 1007239 available at www.maxwell.com. 2. Per Maxwell Document 1007239 available at www.maxwell.com. ½ CV 3. Maximum Peak current (1 sec) = C x ESRDC + 1 4. After 72 hours at 25°C and rated voltage. Initial leakage current can be higher. 0.12V2 5. Per IEC 62391-2, Pd = ESR x mass DC V2 6. Pmax = 4 x ESRDC x mass 7. Emax = ½ CV2 3,600 x mass MOUNTING RECOMMENDATIONS Please refer to the user manual for installation recommendations. Page 4 Document number: 1017119.2 maxwell.com 8. Estored = ½ CV2 3,600 9....

 Open the catalog to page 4

4 3 DATASHEET 2 1 56V MODULE D D BMOD0130 P056 B03 M10 NEGATIVE TERMINAL LEFT SIDE 312.8±2.0 M8 POSITIVE TERMINAL 20.0±1.0 TYP. 218.2 1.0 BMOD0130 P056 BO3 MONITOR CABLE ONLY, 150 MIN C C 175 MAX H T 74.9 2 BRASS INSERT FACE 100.0±2.0 B 135.0 1.0 22 5.1±1.0 218.2 1.0 RIGHT SIDE 17.0±2.0 149.1±2.0 70.6 1.0 L 683 MAX W 5.1±1.0 652.2±3.0 TYPICAL WIDTH FROM BRASS INSERT FACE A BRASS INSERT FACE Part Description BMOD0130 P056 B03 4 L (max) 683 BOTTOM 3 Dimensions (mm) W (max)164.3±1.5 H (max) 177 TYPICAL WIDTH FROM BRASS INSERT FACE 175 A T (±2mm) SIZE 2 CAGE CODE B 68911 SCALE 1:5 74.9 DOC. NO....