for UPS / Backup & Renewable Energy Applications User Manual for 75V Modules: ΃ BMOD0094 E075 B02 > 2007 Maxwell Technologies Inc. TM 1012343.3 size="-1">

 Open the catalog to page 1

USER MANUAL BOOSTCAP ֮ ENERGY STORAGE MODULE DANGER HIGH VOLTAGE HAZARD! Never touch the power terminals as the module can be charged and cause fatal electrical shocks. Always check that the module is fully discharged before manipulating the module. Please refer to the step by step instructions on page 10 for the manual discharge procedure. > The 75V energy module is a self-contained energy storage device entailing containing individual ultra capacitor cells connected together through bus bar connections. Units may be connected in series [up to 4] to obtain higher operating voltages, in...

 Open the catalog to page 2

USER MANUAL BOOSTCAP ֮ ENERGY STORAGE MODULE If the unit is found to be defective or any parts are missing, contact Maxwell Technologies. A Return Material Authorization (RMA) number must be issued prior to returning the unit for repair or replacement. > The 75V module can be mounted in 2 orientations and requires the proper hardware to be used. The 2 supported orientations are: - Horizontal, with connector on the top - Vertical, on the longer side. For this orientation, the module needs to be bolted to a supporting side wall Refer to Figure 1.1 and 1.2 below for overall module dimensions...

 Open the catalog to page 3

Figure 1.1 75V Module Dimensions Figure 1.2 75V Module assembly 2007 Maxwell Technologies Inc. > TM Page 4 of 10 >

 Open the catalog to page 4

USER MANUAL BOOSTCAP ֮ ENERGY STORAGE MODULE DANGER! To avoid arcing and sparking the energy storage module should be in a discharged state and the system power disconnected during installation. The module is shipped discharged. The shorting wire should be removed just prior to making electrical connections. For more information about the discharge procedure please refer to page 10. To provide the lowest possible equivalent series resistance (ESRDC) the high power current path within the module is not fused. Care should be taken within the application to prevent excessive current flow as...

 Open the catalog to page 5

USER MANUAL BOOSTCAP > ֮ ENERGY STORAGE MODULE > Pin Description 1 N/A 2 N/A 3 Thermistor lead 1 or 2 4 Thermistor lead 2 or 1 5 N/A 6 N/A 7 N/A 8 N/A > Figure 1.3: Pin assignment for 8-pin Monitor Connector 75 V Module ֩ 2007 Maxwell Technologies Inc. TM Page 6 of 10 size="-1">

 Open the catalog to page 6

USER MANUAL BOOSTCAP ֮ ENERGY STORAGE MODULE DANGER HIGH VOLTAGE HAZARD! Never touch the power terminals as the module can be charged and cause fatal electrical shocks. Always check that the module is fully discharged before manipulating the module. Please refer to the step by step instructions below for the manual discharge procedure. Do not operate unit above specified voltage. Do not operate unit above specified temperature rating. Do not touch terminals with conductors while charged. Serious burns, shock, or material fusing may occur. Protect surrounding electrical components from...

 Open the catalog to page 8

USER MANUAL BOOSTCAP ֮ ENERGY STORAGE MODULE Prior to removal from the cable removal, or any other handling, ensure that the energy storage module is completely discharged in a safe manner. The stored energy and the voltage levels may be lethal if mishandling occurs. > The module can be stored in the original package, discharged, in a dry place. Observe the maximum storage temperature as stated in the specifications. Discharge used module prior to stock or shipment. > Do not dispose of module in trash. Dispose of according to local regulations. > Refer to data sheets for specifications for...

 Open the catalog to page 9

Asia Pacific Office Maxwell Technologies Asia Room 214, Affiliated Building 3688 Jin Du Road, Shanghai Xinzhuang Industry Park Shanghai 201108, P.R. of China Tel: +86-21-5483-1677 Fax: +86-21-5483-1766 European Office Maxwell Technologies SA CH1728 Rossens, Switzerland Phone: +41 (0) 26 411 85 00 Fax: +41 (0)26 411 85 05 > US Office & Worldwide Headquarters Maxwell Technologies Inc. 9244 Balboa Avenue San Diego, CA 92123, USA Phone: +1 858 503 3300 USA Free call: 1 877 511 4324 Fax: +1-858-503-3301 > Disclaimer of Warranty/Limitation of Liability for Uses in Life Support Devices or Critical...

 Open the catalog to page 10