Brochure LIQUI-VIEW series - Mass Flow ONLINE BV - #4

/ 4


catalogue search
P. 01
P. 02
P. 03
P. 04
Pages:


See other catalogues for Mass Flow ONLINE BV

Text version of the page
MASS-FLOW ONLINE BV www.massflow-online.com E.LVL.0909.A ゥBHT2009-047 > Dimensions and weights Lite version > Indicated pulse unit Lite version > Tubing guidelines Lite version Required straight tube lengths Lite version > Electrical connection Lite version > Process connections (in/out) Each model has an PPS-Resin R male thread type. NPT or Rc female thread is also available as an option. The connectors will be supplied in stainless steel thereby eliminating the risk of damaging threads when using metallic tubing. > Pressure drop (all models) Pressure loss calculation formula > Installation conditions (all models) All information is subject to change without notice. Nominal Scaled pulse Unscaled pulse Frequency @ max. size (mm) [l/pulse] (nominal) [ml/pulse] flow rate [Hz] 4 n.a. 0.0890 750 8 n.a. 0.4408 570 15 n.a. 2.363 320 25 n.a. 12.66 180 Signal cable, 1 meter long (  5.0 O.D. shielded cable) BWN WHT GRN Shielded wire 12 to 24VDC (+) (−) GND Connect shield wire to GND. Pulse output (open collector) Transmission length: 1 kilometer (Using a cable 2.0mmイ in conductor area) 9 8 0 0 ( mm) torque (N・cm) L1 L2 D: Flow monitor I.D. D Horizontal run Vertical run With PPS male thread, avoid forcibly tightening or excessive impact loads. Torque to the specification given below. D H2 51 36 L W H1 39 24 H2 51 36 L W H1 39 24 R (male thread) Nom. D R L W H1 H2 Approx. size (meter I.D.) (conn.) weight* 4 8.5 3/8 80 32 29 68 270 8 13 1/2 80 32 29 68 270 15 14 3/4 85 32 29 68 280 25 24.5 11/4 120 46 46 85 410 Dimensions in mm, weight in g Rc and NPT (female thread) Nom. D Rc NPT L W H1 H2 Approx. size (meter I.D.) (conn.) weight* 4 8.5 1/4 1/4 91 50 29 68 650 8 13 3/8 3/8 91 50 29 68 650 15 14 1/2 1/2 91 50 29 68 650 25 24.5 1 1 126 46 46 85 950 Dimensions in mm, weight (incl. cable) in g Secure a straight tube length 7D min. upstream of, and 3D min. downstream of, the flow monitor. If a throttle valve or expansion tube exists, where the flow path cross section abruptly changes, upstream of the flow monitor, locate it at least 50D away from the flow monitor. Provide a throttle valve downstream of the flow monitor for regulating the flow. For process connection, use tubes having an inside diameter larger than that of the flow monitor. P : Pressure drop [kPa] Po : Pressure drop max. of flowrate is 31 kPa for 4 mm model and 34.3 kPa for other models  : Density of fluid at measurement [kg/m3] o : Standard density: 1000 [kg/m3] Q : Flowrate at measurement [L/min.] Qo : Max. flowrate (Page 2 or 4 stated value) [L/min.] Select an installation location that meets the following requirements: Nominal size I.D. (D) Upstream tube Downstream tube (mm) (mm) (L1) (mm) (L2) (mm) 4 8.5 59 min. 25 min. 8 13 91 min. 39 min. 15 14 98 min. 42 min. 25 24.5 171 min. 73 min.

pageCatalog pdf di En 2012-05-22-30