Malvern Link II - The Universal Interface for System Integrators
8Pages

{{requestButtons}}

Catalog excerpts

Malvern Link II - The Universal Interface for System Integrators - 2

Malvern Link Simplified System Integration Particle analysis and real-time process automation – what’s the link? With the continuing need to drive down the cost of production and maintain a competitive advantage, manufacturers are having to develop innovative, intelligent processing solutions that minimize energy demands, increase efficiency and improve quality. Over the years, a broad range of analytical devices has evolved to provide both the measurement and data control required to reduce operational waste, but only recently has there been a shift towards the real-time integration of...

Open the catalog to page 2
Malvern Link II - The Universal Interface for System Integrators - 3

Malvern Link Simplified System Integration Malvern Link II – one automation protocol System Integrator Responsibility Malvern Responsibility Mastersizer ADI Driver Spraytec ADI Driver Insitec ADI Driver Data Control System Malvern Link II is an OPC-standardized software that simplifies the integration of analytical devices such as those from the Malvern range, with expert systems in process manufacturing. It therefore provides an essential tool for system integration engineers to help reduce the ongoing cost of upgrades and maintenance. • One single interface for remote control and...

Open the catalog to page 3
Malvern Link II - The Universal Interface for System Integrators - 4

Malvern Link Simplified System Integration The OPC-Unified Architecture (UA) Protocol Driven by the Food & Drug Administration (FDA) in the USA, the pharmaceutical industry is now looking to adopt new analytical solutions that provide better process monitoring and system control to promote the use of high level analyzers in the manufacturing process. The resulting Process Analytical Technology (PAT) initiative is the catalyst that has driven the need for a standardized protocol. One such universally accepted and modern interface, which is platform neutral and can achieve the high-speed data...

Open the catalog to page 4
Malvern Link II - The Universal Interface for System Integrators - 5

Malvern Link Simplified System Integration A Typical Installation Configuration Process Interface Dispersion Interface Sample Line Data Control System Analyzer Interface Outlet Interface Process Interface Dispersion Interface A device that extracts sample from the process line. It is possible to have none or more process interfaces in a process configuration. eg auger, flute, valve, at-line feeder, rotary air lock, liquid, piston or screw sampler. A device that transports and disperses the sample. It is possible to have none or more dispersion interface in a process configuration. eg...

Open the catalog to page 5
Malvern Link II - The Universal Interface for System Integrators - 6

Malvern Link Simplified System Integration II A Choice of Three Versions There are three software versions available – depending on the functionality you require. Malvern Link II - Standard Version No need to be an automation engineer to configure the industrial protocol • Configuration Manager offers simple system configuration (Wizard Type) • SOP, Recipe or Sequence designer - Drag and drop action - Take decision on status or value • Customizable User Interface - Document portfolio - Images portfolio • Intelligent Alarm Management - Action on alarm - email notification • Advanced...

Open the catalog to page 6
Malvern Link II - The Universal Interface for System Integrators - 7

Malvern Link Simplified System Integration Malvern Link II ULTRA (Fully compliant with FDA regulations) • 1 CFR Part 11 Compliant 2 E lectronic Record and Electronic Signature • hange Control C SOP versioning Audit trail Action log • dvanced Security A SOP can be assigned to specific user Concept of group - One group is a collection of specific privileges - A user can be part of one or more groups Package Summary Malvern Link II Malvern Link II - ULTRA Automation cabinet OPC server Device configuration Multiple instrument control Alarm email notification Malvern Link II OPC server Remote...

Open the catalog to page 7
Malvern Link II - The Universal Interface for System Integrators - 8

Link Malvern Link Simplified System Integration Evaluation and consultancy We offer a valuable opportunity to assess the importance of accurate particle size distribution analysis and to optimize your process or laboratory set-up without any commitment to purchase. 5 days to find the answers for one small fixed fee Call Malvern to schedule a pre-trial meeting to discuss and agree your particular needs and to identify the goals you wish to achieve. After that, we will make arrangements to deliver an analyzer to your plant accompanied by a specialist consultant from Malvern. To check...

Open the catalog to page 8

All Malvern Panalytical catalogs and technical brochures