Clamp-On Ultrasonic Flowmeter - Malema - #4

/ 4


catalogue search
P. 01
P. 02
P. 03
P. 04
Pages:


See other catalogues for Malema

Text version of the page
Table 1. Sensor choice table
Pipe material
Nominal pipe size D (mm)
Sensor installation *3
Sensor i:ěil length (mm)
Support rail
Code of aenaor *5 combination
Resin *1
EES DŁ SO
V
230
Provided
2
65 S D i iOO
V
230
Hot provided
1
12EŁ DŁ 3O0
V
430 *4
Hot provided
3
Metal *2 PVDF
SUD J iOO
V
230
Hot provided
1
12EŁ 3O0
z
430 *4
Hot provided
4
*1 Resin: PVC or others (Except PVDF]
*2 Metal: SGP, Stainless steel or others (Less than sch.60. In case more than sch.80, consult factory for details] *3 V: Reflex mode (V path], Z: Diagonal mode (Z path]
*4 In case of "480mm" type sensor length, the nominal size is for "more than 125mm", but the installation is possible from 65mm. When the nominal size is for "more or less than 100mm" or if there may be the possibility to change the piping, "480mm" type sensor rail length shall be selected. *5 Refer to the MODEL CODE
Ordering information
• SENSOR
Model code
Description
MUL-S-3 10
-*
Sensor combination
-1
V path, Sensor rail 280mm, Without support rail
-2
V path, Sensor rail 280mm. With support rail
-3
V path, Sensor rail 480mm, Without support rail
„4
Z path, Sensor rail 480mm, Without support rail
Sensor rail band
1
For Nomina! diameter 25mm metal pipe (With 2 bands)
2
For nominal diameter 25mm to 250mm (With 2 bands) 'Except 25mm metal pipe
4
For nominal pipe diameter 300mm (With 4 bands)
Sensor cable length
1
10m [Standard]
2
20m
3
30m
4
40m (Two 20m cables are connected with a relay connector)
Additional functions
(Blank)
NA
Я
Provided *1
• CONVERTER
Model code
Description
MUL-C-3 10
-*
A
Power supply
-A
90 to 250V AC
-0
24V DC
Mounting
1 2
Wall mount type [Standard]
2" pipe mount type
Version
A
Version code
Additional functions
(Blank)
NA
11
Provided '1
CL
4—
CL
Ł с
и
С
С
rz
4—
С
^>
с Ł
*1 If special specification Is required, fill "IT at the end of CODE, and describe it.
SUGGESTIONS
1) Straight length 10D for upstream and 5D for downstream is recommended for accurate measurement. in case pump or valve, expanding piping provided at the upstream 15D straight run is required. (D: Nominal diameter of process piping)
2) The pipe line is to be always full of liquid.
3) it is recommended to install control valves at the downstream side of sensor.
4) it is recommended to provide water tight covers for sensor in case of outdoor installation to avoid problems caused by degrada tion of grease.
ma\ema< flow sensors

pageCatalog pdf di En 2012-05-22-30