Fig. 36: Mobile bypass aggregates
Nominal pressure:
Fineness:
6/10 bar
According to the recommended contamination class; fill filters require a special design
Contamination indicator:
Always necessary for mobile devices, ideally as mechanical/electrical indicator, so that when the contaminant absorption capacity is exhausted, not only is the pump switched off, but an optical signal also indicates the situation at the same time.
Install location:
Usually in the vicinity of the hydraulic fluid tank
Bypass:
Reliable; also required when the pump is switched off through the contaminant indicator
Nominal size of the filter:
Filter capacity should always stand in sufficient ratio to the occurring volume flows. On the other hand, the housing connections are only based on the pump capacity installed in the bypass filter.
Low-pressure High-pressure High-pressure Control Consumer
filter pump filter element
Ô
Feed pump
Bypass filter
Air breather Filling filter
Return line filter
Suction filter
Fig. 37: Filtration in the bypass
29