| | | Fig. 36: Mobile bypass aggregates | | |
| | | |
| | | Nominal pressure: | | Fineness: | | |
| | | |
| | | |
| | | 6/10 bar | | According to the recommended contamination class; fill filters require a special design | | |
| | | |
| | | |
| | | Contamination indicator: | | |
| | | |
| | | Always necessary for mobile devices, ideally as mechanical/electrical indicator, so that when the contaminant absorption capacity is exhausted, not only is the pump switched off, but an optical signal also indicates the situation at the same time. Install location: Usually in the vicinity of the hydraulic fluid tank | | Bypass: | | |
| | | |
| | | Reliable; also required when the pump is switched off through the contaminant indicator | | |
| | | |
| | | Nominal size of the filter: | | |
| | | |
| | | Filter capacity should always stand in sufficient ratio to the occurring volume flows. On the other hand, the housing connections are only based on the pump capacity installed in the bypass filter. | | |
| | | |
| | | Low-pressure High-pressure High-pressure Control Consumer filter pump filter element | | |
| | | |
| | | Ô | | |
| | | Feed pump | | |
| | | Bypass filter | | Air breather Filling filter | | |
| | | |
| | | |
| | | |
| | | Return line filter | | |
| | | Suction filter | | |
| | | |
| | | |
| | | Fig. 37: Filtration in the bypass | | |
| | | |