DI Series | Displacement transducers - 1

DI SERIES DISPLACEMENT TRANSDUCERS FEATU RES ■ Large measuring range: piston displacements from 50 to 1000 mm (80 to 250 mm for DI 63X models) ■ Current-based output signal (4-20 mA) for displacement ■ Built-in temperature measurement (VDC output) ■ Very long life: No moving parts and therefore no wear of components (Eddy-current principle) ■ Insensitive to metallic impurities in the working fluid ■ High shock and vibration resistance ■ Capable of withstanding pressures up to 450 bar ■ Robust construction, designed for permanent operation in hydraulic systems ■ Standard temperature version, up to 80 °C (DI 5XX) ■ High temperature versions, up to 125°C (DI60X and DI61X) or up to 200°C (DI63X) ■ EMC susceptibility conforms to European standards DESCRIPTION Magtrol's line of Displacement Transducers provide contactless measurement of absolute piston position in hydraulic and pneumatic cylinders and other applications. Their robust construction, large insensitivity to shocks and very long life (due to no moving parts and therefore no wear of components) make them both cost effective and very reliable. Magtrol transducers offer a wide range of operational temperatures and admissible pressure resistance for even the most demanding applications. The transducer provides a direct 4 - 20 mA output signal corresponding to the measuring range, as well as VDC temperature output. As an option Magtrol offers the CST 113 Signal Converter, which allows the complete chain to be calibrated according to the specific needs, either in current or voltage output. APPLICATIONS The DI Series of displacement transducers were developed principally for OEM applications in the hydraulic industry. They enable the direct and reliable measurement of the position of: ■ Hydraulic Cylinders ■ Steam Inlet Valves ■ Control Valves ■ Propellers ■ Servo Controls ■ Stone Crushers Their design is such that the installation cost is kept to a minimum. This cost-effectiveness results from the limitation to one fixed standard signal of 4 - 20 mA with very precise determination of the measurement interval (from 0 to full scale) on the sensing element. SYSTEM CONFIGURATION ◄- POWER SUPPLY: 20 to 32 VDC / min. 70mA -► DISPLACEMENT SIGNAL: 4 to 20 mA (20 to 4 mA for DI 63X only) -► TEMPERATURE SIGNAL: 7.5VDC ±80mV at 20°C +30mV/°C (DI 5XX) 7.5VDC ±60mV at 20°C +10mV/°C (DI 6XX) © 2020 MAGTROL | Due to continual product development, Magtrol reserves the right to modify specifications without forewarning. Page 1 / 7

Open the catalog to page 1
DI Series | Displacement transducers - 2

DI SERIES OPERATING PRINCIPLES EDDY-CURRENT PRINCIPLE CHARACTERISTICS OF THE OUTPUT SIGNAL Magtrol DI Series Displacement Transducers use the principle of Eddy-current measurement. An aluminum tube moves along the transducer’s coil changing the induced Eddy-current losses, thus changing the coil impedance. An electronic circuitry housed in the transducer head, transforms the information of the measuring tube position into a linear signal. This circuitry uses modern SMD (surface-mounted device) technology, giving it robustness and reliability. The sensor is actively compensated for...

Open the catalog to page 2
DI Series | Displacement transducers - 3

H MAGTROLSPECIFICATIONSMODEL MEASURING RANGES a) a) Refer to dimension section b) According to "Linear Measuring Range" dimension (see dimension section) c) Calibrated standard signal. Transducer and measuring tube are calibrated in the factory for standard measuring ranges mentioned at the top of this table in section «Measuring Ranges» d) of FSD (Full Scale Deflection) © 2020 MAGTROL | Due to continual product development, Magtrol reserves the right to modify specifications without forewarning.

Open the catalog to page 3
DI Series | Displacement transducers - 4

D (Linear Measuring Range) NOTE: Original dimensions are in metric units. Dimensions converted to English units have been rounded up to 4 decimal places. a) Each DI Series Displacment Transducer is delivred with its dedicated measuring tube. NOTE: 3D STEP files of most of our products are available on our website: www.magtrol.com ; other files are available on request. © 2020 MAGTROL | Due to continual product development, Magtrol reserves the right to modify specifications without forewarning.

Open the catalog to page 4
DI Series | Displacement transducers - 5

H MAGTROLDIMENSIONS DI 63X_ NOTE: Original dimensions are in metric units. Dimensions converted to English units have been rounded up to 4 decimal places. a) Each DI Series Displacment Transducer is delivred with its dedicated measuring tube. b) The models DI 63X are also available with protection cover (see above) and 3 meter cable. Please contact Magtrol. NOTE: 3D STEP files of most of our products are available on our website: www.magtrol.com ; other files are available on request. © 2020 MAGTROL | Due to continual product development, Magtrol reserves the right to modify specifications...

Open the catalog to page 5
DI Series | Displacement transducers - 6

H MAGTROLDIMENSIONS DI 5XX WITH THREADED HEAD NOTE: Original dimensions are in metric units. Dimensions converted to English units have been rounded up to 2 decimal places. NOTE: 3D STEP files of most of our products are available on our website: www.magtrol.com ; other files are available on request. © 2020 MAGTROL | Due to continual product development, Magtrol reserves the right to modify specifications without forewarning. Page 6 / 7 DATASHEET www.magtrol.com

Open the catalog to page 6
DI Series | Displacement transducers - 7

DI SERIES SYSTEM OPTIONS AND ACCESSORIES CONNECTION CABLES (DI 5XX & DI 6XX) ORDERING NUMBER 4 : Axial connector 5 : 90° connector ~65 mm (2.56 in) Cable with axial connector 1 : Cable length 3 m 2 : Cable length 5 m 3 : Cable length 10 m a) a) Other longer cables lenghts avaible on request. Cable with 90° connector COUNTER CONNECTOR Axial connector CST 113 SERIES - SIGNAL CONVERTER The CST  113 is a signal converter for transducers delivering a signal of 4 to 20  mA. Either a voltagebased signal (I/V conversion) or a current-based signal (I/I) can be chosen as the converter output, along...

Open the catalog to page 7

All MAGTROL catalogs and technical brochures

  1. 4 QUADRANT

    2 Pages

  2. ZM Series

    5 Pages

  3. SK-01 Series

    3 Pages

  4. AMF Series

    3 Pages

  5. WB23 & WB27

    7 Pages

  6. Model 5200

    1 Pages

  7. 5211

    1 Pages

  8. 5251-2

    1 Pages

  9. SBB 14

    3 Pages

  10. FMF SERIES

    5 Pages

  11. ZS Series

    7 Pages

  12. RSB

    1 Pages

  13. PC-150

    2 Pages

  14. PCB

    1 Pages

  15. CST 113

    4 Pages

Archived catalogs

  1. WB/PB 65

    8 Pages

  2. WB/PB 15

    8 Pages