AN 2000 C Load Monitor/ Signal Conditioner/Display - MAGTROL - #1

/ 5


catalogue search
AN 2000 C Load Monitor/ Signal Conditioner/Display - MAGTROL
P. 01
AN 2000 C Load Monitor/ Signal Conditioner/Display - MAGTROL
P. 02
AN 2000 C Load Monitor/ Signal Conditioner/Display - MAGTROL
P. 03
AN 2000 C Load Monitor/ Signal Conditioner/Display - MAGTROL
P. 04
AN 2000 C Load Monitor/ Signal Conditioner/Display - MAGTROL
P. 05
Pages:
AN 2000 C Load Monitor/ Signal Conditioner/Display - MAGTROL


See other catalogues for MAGTROL
You may also be interested in

Monitor, Tester, Digital display, Position sensor, Load pin


Text version of the page
The AN 2000 C is used with Magtrol Load Measuring Pins to measure load and force and provide overload protection. Magtrol also offers a wide range of Load-Force- Weight Transducers in various executions and accuracy classes and our Load Monitoring Units (LMUs) constitute an ideal safe measurement system which continuously checks for short-circuits and interrupted signal lines. AN 2000 C Data Sheet AN 2000 C Load Monitor/ Signal Conditioner/Display 1 www.magtrol.com MAGTROL Features • 1 to 4 Transducer Power Supplies: 5 V or 10 V / 120 mA DC • 5 Red Digits (±32000), 14 mm Height, 96 × 48 mm Format • 16 Acquisitions per Second • Logic Inputs for Remote Functions • Hold, Tare, Peak and Valley Functions • Panel or DIN Rail Mounting • IP 65 Front Panel (indoor use) • 1 to 3 Flexible Configurations with Interchangeable Options: • 2 or 4 thresholds (relays) • 0–10 V / 4–20 mA analog output • RS-232C or RS-485 serial output • Programmable with Front-Panel Keys • Quick Wiring Using WAGO Connectors Options • Relay Outputs (thresholds): 2 SPDT or 4SPST • Analog Output: 0-10 V or 4-20 mA • Serial Output: RS-232C or RS-485 Description The AN 2000 C Load Monitor is designed to process and display signals coming from various types of transducers (weight, load, pressure, torque, etc.) that use standard strain-gauge bridges. It can also receive any signal within the range ±300 mV DC coming from a shunt, a converter or any type of transmitter. The monitor provides selectable input ranges (15 mV, 30 mV, 60 mV or 300 mV) and excitation voltages (5 V or 10 V) to accommodate cells of various types and sensitivities. Two programming methods allow scaling the meter to operate in the desired engineering units. The basic instrument consists of a PCB assembly including the main board, the display and the power supply filter, to which the A/D conversion circuit and the input option are added. The latter two elements are connected by their own connectors. The functions of the basic instrument include the display of the input variable as well as the remote freezing of the display (HOLD), the reading of the stored minimum and maximum values (PEAK & VALLEY) and the TARE function with reset to zero. System Configuration LIMIT MAX / MIN DATA ENTER TARE RESET ESC C AN 2000 TARE HOLD LIMIT MAX MIN DATA INP1 DSP1 INP2 DSP2 FLT STORE RUN PROG A B 1 2 3 4 AN 2000 C Load Monitor/ Signal Conditioner/Display LB 2XX Transducer

pageCatalog pdf di En 2012-05-22-30