Maximum Magnetic Field In Air (Flux density) - 11843 MAXIMUM FIELD STRENGTH IN AIR(Flux density)

in our production coils with different impulse magnetizers Magnetization coilsIM- 1420IM- 2525IM- 5025IM- 8530IM-17030IM-25030IM-34030 1" F4,88,510,0**** 2"F3,04,05,56,58,5** 3" F1,72,43,54,14,85,56,6 4" F1,11,62,32,83,54,25,0 5" F0,81,21,62,02,43,03,6 6" F1,31,62,12,42,7
All values in Tesla All magnetization coils above the coloured lines are able to magnetize the following materials::FerriteSm 1 Co 5 Sm 2 Co 17 and NdFeB * Stronger fields are possible with these coils if care is takenthat the coils do not overheat.
MAGNET-PHYSIK Dr. Steingroever GmbH MAGNET-PHYSICS INC. Emil-Hoffmann-Strasse 3, D-50996 Köln 225 N. Arlington Hts. Road / Suite 207, Elk Grove Village,IL 60007, USA Phone : ++49 / (0)2236 / 39 19-0 Fax: ++49 / (0)2236 / 39 1919 e-mail: info@magnet-physik.deWebsite: www.magnet-physik.de Phone: ++1 847 7589641 Fax ++1 847 7589646 e-mail: info@magnet-physics.comWebsite: www.magnet-physics.com 1998/03Max. Field Strength© MAGNET-PHYSIKDr. Steingroever GmbH, Köln 2003