Impulse Magnetizer K-series - MAGNET-PHYSIK - #2

/ 2


catalogue search
P. 01
P. 02
Pages:


See other catalogues for MAGNET-PHYSIK
You may also be interested in

Magnetizer, Demagnetizer, Sensor, Scanner, Gaussmeter


Text version of the page

Technical Data

IM-K-...-A-... IM-K-...-D-... IM-K-...AD-... Type of discharge: aperiodically damped damped oscillation aperiodically damped + damped oscillation Maximumg energy: 5000 Ws / 10000 Ws 4000 WS / 8000 Ws 4000 Ws / 8000 Ws Maximum voltage: 2000 V 2000 V 2000 V Voltage setting accuracy: 1,0 V 1,0 V 1,0 V Maximum current: 25000 A 25000 A 25000 A Cycle time at max. energy, approx: 7 s / 12 s 6 s / 10 s 6 s / 10 s High current output: 1 1 1 Control: Simatic SPS S7, Software updates via Micro Memory Card Operation:
Display with keyboard remote via 24 V interface
Interfaces RS 232, Profibus (optional) Current measurement:
Measurement of impulse current
Option: Synchronous operation Supply: 1-phase: 230 V AC ± 10 %, 50/60 Hz, 16 AWeight:
ca. 140 kg / ca. 170 kg ca. 140 kg / ca. 170 kg ca. 140 kg / ca. 170 kg Dimensions (with casters and lift rings) - Width: 480 mm - Height: 840 mm - Depth: 900 mm

Impulse Magnetizer K-series - 11843 ?

Safety Functions

Safety is a key area for Magnet-Physik. Operation without interruption and protection of the operator. The Siemens Programmable Logic Controller (PLC) controls all basic functions continuously. The PLC can safely shut down the magnetizer should any out of control conditions occur. In case of a fault or interruption the capacitors are discharged automatically and disconnect the mains. For safety reasons, we do not allow direct control of our PLC. Alteration of internal programs is not allowed. Your inputs are checked against our software at all times. Only permitted functions are allowed per the programming of our PLC. Your production line can communicate with our machines via several interfaces. Normal communications are via 24-volt signals. This allows for status monitoring and activation of the machine. We also offer Profibus and RS232 communications protocols as an option. Maintenance is minimized. Most parts in our machine are standard and can be replaced around the world. The few specialized items are in stock

and available for express shipment within 24 hours.

Front connections covered with interlocked steel panel protecting the user from high voltage

MAGNET-PHYSIK Dr. Steingroever GmbH MAGNET-PHYSICS Inc.

Emil-Hoffmann-Straße 3, D-50996 Köln Phone: +49 / (0)2236 / 3919-0 9001 Technology Drive Suite C-2, Fishers, IN 46038, USA Phone: +1 317 577 8700 Fax: +49 / (0)2236 / 3919-19 Fax: +1 317 578 2510

e-mail: info@magnet-physik.de Website: www.magnet-physik.de e-mail: info@magnet-physics.com Website: www.magnet-physics.com

2119/08 Impulse magnetizers K-Series© MAGNET-PHYSIK Dr. Steingroever GmbH, Köln 2008