LT11A - Magnescale Europe GmbH - #1

/ 1


catalogue search
LT11A - Magnescale Europe GmbH
P. 01
Page:
LT11A - Magnescale Europe GmbH


See other catalogues for Magnescale Europe GmbH

Text version of the page
Dimensions Dimensions • Compact size : DIN standard (72 mm x 72mm / 2.83" x 2.83" W x H) • Resolution: 1, 5, 10 μm Selectable • Suitable for panel mounting • Direct interfacing from display unit to PLC or computer • Current values, maximum, minimum, peak-to-peak values and GO/NO GO evaluation included as standard functions. • ADD/SUB function (2-channel model) • Full lineup for various applications • Compact size : DIN standard (72 mm x 72 mm / 2.83" x 2.83" W x H) • Resolution : 5,10 μm Selectable • Suitable for panel mounting • Direct interfacing from display unit to PLC or computer • Current values, maximum, minimum, peak-to-peak values and GO/NO GO evaluation included as standard functions. • ADD/SUB function (2-channel model) • Full lineup for various applications Counter unit Counter unit Compact, lightweight, and easy-to-mount counter. Compact, lightweight, and easy-to-mount counter. LT LT11A SERIES (for DT512) LT LT10A SERIES (for DT12/32) /2.67 +0.03 +0.015 68 +1.0 +0.4 4-R1 or less /2.67 +0.03 +0.015 68 +1.0 +0.4 68/2.67 73/2.87 68.1/2.68 74/2.91 78/3.07 88/3.46 16/0.62 1/0.03 33/1.29 60/2.36 2-R2 15/0.59 Unit : mm/inch /2.67 +0.03 +0.015 68 +1.0 +0.4 4-R1 or less /2.67 +0.03 +0.015 68 +1.0 +0.4 68/2.67 73/2.87 68.1/2.68 74/2.91 78/3.07 88/3.46 16/0.62 1/0.03 33/1.29 60/2.36 2-R2 15/0.59 Unit : mm/inch Model LT11A-101 101B 101C 201 201B 201C Common Specifications Note 1 : I/O connector Input : Reset, peak-hold start, peak-hold pause, RS trigger (RS-232C models only) Output : Result evaluation (photocoupler) Note 3 : RS-232C (8 pin mini-DIN connector) Reset, preset value setting/recall, peak-hold start, peak-hold pause,current value hold, software version read, comparator value setting, current value/maximum value/minimum value/peak-to-peak measuringmode selection and output, key lock and release. Note 2 : BCD (36 pin half-pitch connector) Input : Reset, peak-hold start, comparator value selection (4 settings) Output : five digits (open collector)One of current value/maximum value/minimum value/peak-to-peakvalue selected and output. Alarm output Note 4 : RS-TRG pin Trigger input for RS-232C data output Note 5 : With measuring unit connected. Display Reset function Preset function Conparetor function Peak hold function Resolution Direction Maximum response speed Addition and subtraction function Alarm Data storage Temperature Power consumption *5 Mass Power voltage Compatible measuring unit I/O 5 digit backlit LCD, mode display Reset key or external input (I/O connectors) Preset value set with preset key, recalled with reset key. Maximum, minimum, and peak-to-peak values. Measuring started by the start input of the I/O connector; update stop by pause input. 0.001 mm, 0.005 mm, 0.01 mm selectable Can be switched Displayed on LCD or the I/O connector’s comparator outputs are all “H” (OFF). Operating temperature: 0 to 40°C Storage temperature: |10 to 50°C Resolution, direction, comparator value, preset value, modes, etc. Power input connector (3 pins) : DC9.0 to 26.4 V. DT512 series Three-level comparator Comparator value set with keys on the front panel. Result evaluation: LED and I/O connector output (photocoupler) 1 channel 2 channel „Ÿ „Ÿ „Ÿ „Ÿ 100 m/min „Ÿ BCD sign Data signalling rate, etc. BCD sign Data signalling rate, etc. 80 m/min A+B, A|B, B|A can be set with the direction setting. „Ÿ „Ÿ › BCD terminal RS-232C command Recalled with BCD reset terminal Up to 4 values can be set for comparator (key input). Switched with BCD terminal. Set or recalled with RS-232C command Set with RS-232C command Recalled with BCD reset terminal Set or recalled with RS-232C command „Ÿ „Ÿ Can be started with the BCD terminal. BCD alarm terminal “H” (OFF) BCD alarm terminal “H” (OFF) RS-232C can set or start. „Ÿ „Ÿ „Ÿ „Ÿ „Ÿ 1.8 W Approx. 200 g 2.9 W Approx. 230 g 2.0 W Approx. 220 g 2.3 W Approx. 210 g 4.0 W Approx. 270 g 2.5 W Approx. 230 g „Ÿ „Ÿ Can be started with the BCD terminal. RS-232C can set or start. „Ÿ „Ÿ Up to 4 values can be set for comparator (key input). Switched with BCD terminal. Set with RS-232C command „Ÿ „Ÿ BCD terminal RS-232C command › „Ÿ › › „Ÿ › › „Ÿ › Measuring unit input I/O connectors *1 BCD *2 RS-232C *3 RS-TRG *4 Model LT10A-105 105B 105C 205 205B 205C Common Specifications Note 1 : I/O connector Input : Reset, peak-hold start, peak-hold pause, RS trigger (RS-232C models only) Output : Result evaluation (photocoupler) Note 3 : RS-232C (8 pin mini-DIN connector) Reset, preset value setting/recall, peak-hold start, peak-hold pause,current value hold, software version read, comparator value setting, current value/maximum value/minimum value/peak-to-peak measuringmode selection and output, key lock and release. Note 2 : BCD (36 pin half-pitch connector) Input : Reset, peak-hold start, comparator value selection (4 settings) Output : five digits (open collector)One of current value/maximum value/minimum value/peak-to-peakvalue selected and output. Alarm output Note 4 : RS-TRG pin Trigger input for RS-232C data output Note 5 : With measuring unit connected. Display Reset function Preset function Conparetor function Peak hold function Resolution Direction Maximum response speed Addition and subtraction function Alarm Data storage Temperature Power consumption *5 Mass Power voltage Compatible measuring unit I/O 5 digit backlit LCD, mode display Reset key or external input (I/O connectors) Preset value set with preset key, recalled with reset key. Maximum, minimum, and peak-to-peak values. Measuring started by the start input of the I/O connector; update stop by pause input. 0.005 mm, 0.01 mm selectable Can be switched Displayed on LCD or the I/O connector’s comparator outputs are all “H” (OFF). Operating temperature: 0 to 40°C Storage temperature: |10 to 50°C Resolution, direction, comparator value, preset value, modes, etc. Power input connector (3 pins) : DC9.0 to 26.4 V. DT12/32 series Three-level comparator Comparator value set with keys on the front panel. Result evaluation: LED and I/O connector output (photocoupler) 1 channel 2 channel „Ÿ „Ÿ „Ÿ „Ÿ 100 m/min „Ÿ BCD sign Data signalling rate, etc. BCD sign Data signalling rate, etc. 80 m/min A+B, A|B, B|A can be set with the direction setting. „Ÿ „Ÿ › BCD terminal RS-232C command Recalled with BCD reset terminal Up to 4 values can be set for comparator (key input). Switched with BCD terminal. Set or recalled with RS-232C command Set with RS-232C command Recalled with BCD reset terminal Set or recalled with RS-232C command „Ÿ „Ÿ Can be started with the BCD terminal. BCD alarm terminal “H” (OFF) BCD alarm terminal “H” (OFF) RS-232C can set or start. „Ÿ „Ÿ „Ÿ „Ÿ „Ÿ 1.8 W Approx. 200 g 2.9 W Approx. 230 g 2.0 W Approx. 220 g 2.3 W Approx. 210 g 4.0 W Approx. 270 g 2.5 W Approx. 230 g „Ÿ „Ÿ Can be started with the BCD terminal. RS-232C can set or start. „Ÿ „Ÿ Up to 4 values can be set for comparator (key input). Switched with BCD terminal. Set with RS-232C command „Ÿ „Ÿ BCD terminal RS-232C command › „Ÿ › › „Ÿ › › „Ÿ › Measuring unit input I/O connectors *1 BCD *2 RS-232C *3 RS-TRG *4 (71.8) 2 68 68 8 68 2 BCD OUT.B BCD OUT.A 1234 1234 BA A+B CPL CPH P-P P-P MIN MAX MIN MAX COMP SET B A RESET RESET MODE 72 72 (71.8) 2 68 68 8 68 2 BCD OUT.B BCD OUT.A 1234 1234 BA A+B CPL CPH P-P P-P MIN MAX MIN MAX COMP SET B A RESET RESET MODE 72 72 LT11A LT10A 46 47

pageCatalog pdf di En 2012-05-22-30