You may also be interested in
Light source, Spray, Detector, Permanent magnet, Magnet
Text version of the page
DYE PENETRANT INSPECTION Most convenient forField useLtd ITWVivid red colour requiresflaw detection spray - 21689 SPOTCHECKNo ultra violet lightDivision of fiWidely used for weldinspectionREDDYEPENETRANTTESTINGMAGNAFLUX SPOTCHECK PRODUCTS SKC-S : A volatile petroleum distillate based solvent for removal of surfaceexcess penetrant in a solvent wipe method. Can also be used to removeFlash Point (PMCC)Viscosity at 20 C C7CS Organic contaminants prior to penetrant testing.Specific Gravity0.72 SKL-SP1 : Deep red penetrant for use with solvent wipe or post removable/Flash Point (PMCC)> 93 C emulsifiable systems. Ideal for testing smooth castings, forgings, fabrications,Viscosity at 38 C3.2 CS welds, etc. both in manufacture and during service.Specific Gravity0.85 SKL-WP : Deep red water washable penetrant ideal for inspection of roughFlash Point (PMCC)> 93 C castings, welds and other rough surfaces where the ease of removal by waterViscosity at 38 C10.0 CS Washing is required,Specific Gravity0.99 SKD-S2 : A suspension of white developer in a blend of volatile nonFlash Point (PMCC)1 C halogenated solvents SKD-S2 must be agitated thoroughly prior toSpecific Gravity0.92 Application and must be applied by spray. ZR10B : A pink concentrate for dilution in water, 5 to 30% v/v solutions areAqueous solutions will freeze Ideal for removal of excess SKL-SP1 after water pre-rinse. Simpleclose to 0 C all temperatures immersion is sufficient and contact times up to 2 minutes are commonly foundshould not exceed 40 C useful. The above figures are typical values only and do not constitute a Specification |
|