ANALOG AND DIGITAL ELECTRONIC TIMERS

Ideal for: Automatic Drain Valves - Sampling Valves - Lubrication Systems - Air Dryers

ANALOG TIMER TECHNICALSPECIFICATIONS SERIES: AT2000

Supply voltage: 120 240V AC/DC - 50Hz/60Hzfor and CE approved Timer >
(Code AT2000C02I*) Absorption:4 mA Max
Operating temperature: - 10 C + 50簰 C
Class protection: IP 65 - EN 60529 >
(with connector and gasket) Switch holding voltage: 400V MaxSwitch capacity: 1A
Inrush current:10A for 10 ms
Duty cycle: 100% ED
Switch life: 310 >
8 Repeat accuracy: Ա 1%
Timing temperature coefficient: 0.005% - CѰ
Time ON: from 0.5 to 10 s.
Time OFF: from 30 s. to 45 min.
Set/Reset/Test: Membrane key
Circuit: UL 94 V0
Indicators: GREEN LED for "power ON"RED LED for "valve open"Manual override: Test
Colour: Black >

DIGITAL TIMER TECHNICALSPECIFICATIONS

Supply voltage:120 240V AC/DC - 50Hz/60Hzfor and CE >

SERIES: DT3000

approved Timer >
(Code DT3000C12I*) Absorption: 4 mA Max
Operating temperature: - 10 C + 50簰 C
Class protection: IP65 - EN 60529 >
(with connector and gasket) Switch holding voltage: 400V Max
Switch capacity: 1A
Inrush current: 10A for 10 ms
Duty cycle: 100% ED
Switch life:310 >
8 Repeat accuracy:Ա 0.01%
Timing temperature coefficient: 0.0001% - CѰ
Time ON:from 0 to 9.5 s., step 0.5 s.from 10 to 99 s., step 1.0 s.Time OFF:from 0 to 9.5 min., step 0.5 min.from 10 to 99 min., step 1 min.Indicators: GREEN LED for "power ON"RED LED for "valve open"Manual override: Test
Colour: Black* approval number E200580 >
For supply voltage 24V AC/DC please contact Sales Department. All dimensions in millimetres Note: Timers are supplied in single boxes with two squared gaskets and M3X50 fixing screw (see assembling scheme) 43 size="-3">

Solenoid valve catalog
  1. P. 1

  2. P. 40

    2/2 WAY DIRECT ACTING SOLENOID VALVE, G 1/8" - G 1/4" HIGH PRESSURE > normally closed TYPE: D262/263 TECHNICALSPECIFICATIONS Media: water, steamMedia...
  3. P. 41

    2/2 WAY PILOT OPERATED PISTON VALVE, G 1/4" G 1/2" HIGH PRESSURE normally closed TYPE: D634/635/636DTT1 TECHNICALSPECIFICATIONS Media: water, air,...
  4. P. 42

    'ntemational ■3/2 WAY DIRECT ACTINGSOLENOID VALVE, G 1/4" + G 1/2"FOR VACUUMnormally closed type d337/338/339cvu1technical SPECl rcat10nsMedia:...
  5. P. 43

    internationalPI LOT OPERATOR FOR USE IN DANGEROUS ATM OSPHERES (ATEX)SERIES: NTHE FOLLOWING M&M VALVES CAN BE FITTED WTH EXPLOSION- PROOF OPERATOR,...
  6. P. 44

    COILS FOR M&M INTERNATIONAL SOLENOID VALVES Coils manufactured by M&M International are designed for continuous duty in conformity to the EN60730...
  7. P. 45

  8. P. 46

    VALVE SELECTION A solenoid valve should be chosen whenever the following conditions are met: Media with few dirt particles Moderate flow volumes Average...
  9. P. 47

    OPTIONAL FEATURES Manual Override (M) Normally closed direct acting and pilot operated solenoid valves can be supplied with a manual override whichallows...
  10. P. 48

    VALVE INSTALLATION To ensure trouble-free operation please observe the following: Safety Always connect the coil's earth terminal to ground to ensure the...
  11. P. 49

    TECHNICAL INFORMATION PAGE For additional technical information please copy this page and fax it to us duly completed at No. +39 035 531763We will be pleased...
  12. P. 50

    CE MARKING The CE mark indicates that the product satisfies all the regulations governing safety laid down by theEuropean Community. Products displaying...
Text version

All M & M INTERNATIONAL catalogues and technical brochures

  1. D887

    1 Pages

    En
  2. D606/622

    1 Pages

    En
  3. D232-234

    1 Pages

    En
  4. D204

    1 Pages

    En
  5. D223-225

    1 Pages

    En