Embracing Challenge Gas Sample Probe Series SP® Version SP2600-H/C/I/BB/F/1K190 and SP2600-H/C/I/BB/F/0,1GF190 Special Features Filter element with particularly large filter surface O ptimum operational reliability Universal applicability Adaption to nearly all process condi- tions due to its compact and modular design Easy mounting and maintanance Small volume, fast response time Integrated possibility for back-flushing and shut off the sample outlet Easy operation and maintenance Application The probes M&C type SP2600-H/C/I/BB/F..., based on type SP2000-H (see data sheet 2.2.2), are used for continuous ­ as sampling g in processes with gases of high dust content, high temperatures and/or high humidity. Due to the particularly large filter surface and the possibility to back purge the filter element, this type of probes achieve a very long service life especially in those cases where no pre-filters can be used. For this purpose, a back purge valve and a pneumatic isolation valve for the measuring gas outlet are integrated inside the probe. Version SP2600-H/C/I/BB/F/0,1GF is suitable for dusts with extremely fine particles of up to 0,1 µm grain size. Version SP2600-H/C/I/ BB/F/1K200 can be back purged very efficiently due to its double-ply constructed filter element with an external filter membrane of 1 µm filter porosity. Description The sample probes are designed for easy installation, reliable operation, trouble free maintenance and a versatile application. Depending on the application, different sample tubes (see data sheet 2-1.1.0.6), not included in the scope of delivery of the probe, are screwed into the thread (G3/4”i) of the filter housing. This ensures reliable operation ­ xternal to the e process preventing the temperature ­ alling f below the dew-point. The temperature of the standard probe is controlled by an integrated compact design capillary sensor ­ hermostat with an excess t temperature limit switch and an alarm function for ­ emperature failure in compact t arrangement directly to the probe. Feeding the test gas is possible via an integrated check valve. Additional functions of the probe SP2600H/C/I/BB/F...: • Calibration gas will be injected into the probe through a check valve /C directly to the sample outlet. No calibration gas is lost into the stack. • An isolation valve /I shuts off the sample outlet from the internal filter area. • Through a high flow rate check valve / BB/F, which is fixed to the filter housing wall, blow back of the incorporated ceramic filter element will be done incl. the filter area and the insitu probe tube or the pre-filter. The large surface filter element of ceramic or glass fiber is placed in a housing with low stagnant space outside the process. The probes are constructed in such a way that changing the filter element does not require the sample line to be dismounted and, therefore, the contamination of the clean gas is avoided. The special design of the heating element of the SP2600... (with protective hood) ­ ermits p controlled heating of the complete filter housing including the mounting flange up to 180 °C (Version /H320 up to 320 °C). Technical specifications and illustrations are without obligation, subject to modifications. 03.03/02.08 M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111

 Open the catalogue to page 1

n case of higher ambient temperatures use option PT100 (Part No. 20S9025) or thermocouple Fe-CuNi respectively Ni-CrNi (Part No. 20S9027 res p. 20S9028) instead of the thermo- Thermostat,Temperature adjustment 0-180°C* /PT100** /Fe-CuNi** /Ni-CrNi** Ready for operation after 40min Low temperature alarm contact Change-over contact Contact rating: 250V, 3A-, 0,25A= Alarm point: AT 30°C Sample gas outlet connection 1x 1/4" NPTi* tube connectors 0 6,8 or 10 mm** Backflush/Test gas connection backflush: tube 0 8mm, span: tube 0 6mm Shut off valve connection /I 1/8"NPT i Pressure range contol air/I...

 Open the catalogue to page 2

Sample tube Test gas in Sample gas out Isolation valve Sample tube Purge gas Control Test gas Technical specifications and illustrations are without obligation, subject to modifications. 03.03/02.08 M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany

 Open the catalogue to page 3

All M&C TechGroup Germany catalogues and technical brochures

  1. FPF-0.1GF

    2 Pages

    En
  2. FP-2GF

    4 Pages

    En
  3. SP2000/V20

    3 Pages

    En
  4. SP2000/PV

    2 Pages

    En
  5. PSP4000-H

    4 Pages

    En
  6. SP3000/Ex

    4 Pages

    En
  7. PSP4000-H/C

    4 Pages

    En
  8. SP3200/EX

    6 Pages

    En
  9. SP3100/EX

    6 Pages

    En
  10. SP2500-H/C/I/BB

    4 Pages

    En
  11. SP2020-H

    2 Pages

    En
  12. SP2200-H/C/I/BB

    2 Pages

    En
  13. SP2300-H

    4 Pages

    En
  14. SP10-H

    3 Pages

    En
  15. SP180-H

    2 Pages

    En
  16. SP10

    3 Pages

    En
  17. SP2100-H

    2 Pages

    En
  18. SP210-H/W

    2 Pages

    En
  19. SP52/53

    2 Pages

    En

Archived catalogues

  1. SP3000/EX

    4 Pages

    En