SP2000/PV - 2 Pages

  1. P. 1

  2. P. 2

Catalogue excerpts

Embracing Challenge Sample Tubes for Gas Sample Probes Series SP® with G 3/4”-connection thread Sample tubes for series SP® Special Features Sampling of dust loaded process gases S mall volume, fast response time Application The M&C sample tubes are used in combination with the M&C gas sample probes series SP® for point selective continuous gas sampling in processes with low dust loadings. Easy mounting and maintenance S elf-regulated electrical heater Alarm contact for low temperature Outdoor mounting with protective cover Insitu probe tube optional Description The M&C probe sample tubes SP210/SS and SP2000/... are selected according to the specific applications. Influencing process parameter are the gas composition, dust content, water vapure saturation, temperature, pressure and gas velocity. Among the standard length “L1” other lengths up to “L max” are available on request. For applications with low sample gas flow, sample tubes SP2000/SS-Vm are ­ quipped e with volume displacers to decrease the retention time. Gas sampling downstream a wet scrubber with a high content of water carried out with the M&C sampling tube SP32, equipped with an integrated demister for liquid drop collection. Depending on the selected material, the M&C sample tubes are equipped with a welded thread adapter or a support adapter. They are partly made of different material than the tubes, depending on fabrication. See below table. The connection thread enables an easy mounting into the mounting flange of the M&C gas sample probes. Further sampling accessories: For a high dust load Pre-filter V20.., V12... For lower deviation of dew point on process side heated sample tubes SP30, SP35. Technical specifications and illustrations are without obligation, subject to modifications. 09.96/06.11 M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111

 Open the catalogue to page 1

Sample tubes Series SP' Sample tube SP210SS / SP2000... / CR-N with welded thread connection Sample tube SP2000/ CR-2(20) /AO for >1300 C with support adapter Sample tube SP32 with demister for gas sampling behind wet scrubber Technical Data sample tube Temperature Material Length Length max.°C Tube/connection part „L1"" „L max" * Sannple tube with support adapter. Max.Tennperature concern the area of the support adapter on approx. 200 nnnn length depend on materia 600/900 °C 2) Please pay attention to the characteristic feature of ceramic in case of high and changing temperatures1 Other materials...

 Open the catalogue to page 2

All M&C TechGroup Germany catalogues and technical brochures

  1. FPF-0.1GF

    2 Pages

    En
  2. FP-2GF

    4 Pages

    En
  3. SP2000/V20

    3 Pages

    En
  4. PSP4000-H

    4 Pages

    En
  5. SP3000/Ex

    4 Pages

    En
  6. PSP4000-H/C

    4 Pages

    En
  7. SP3200/EX

    6 Pages

    En
  8. SP3100/EX

    6 Pages

    En
  9. SP2500-H/C/I/BB

    4 Pages

    En
  10. SP2020-H

    2 Pages

    En
  11. SP2200-H/C/I/BB

    2 Pages

    En
  12. SP2300-H

    4 Pages

    En
  13. SP10-H

    3 Pages

    En
  14. SP180-H

    2 Pages

    En
  15. SP10

    3 Pages

    En
  16. SP2100-H

    2 Pages

    En
  17. SP210-H/W

    2 Pages

    En
  18. SP52/53

    2 Pages

    En

Archived catalogues

  1. SP3000/EX

    4 Pages

    En