SP180-H - 2 Pages

  1. P. 1

  2. P. 2

Catalogue excerpts

Embracing Challenge Gas Sample Probe Series SP® Electrically heated, compact version with weather protection cover and test gas connection as standard SP180-H Special Features Sampling of dust loaded process gases S mall volume, fast response time Easy mounting and maintenance Application The M&C gas sample probe version SP180-H is applicable for continuous gas sampling. The compact design requires only limited space. The gas sample probe is equipped with a new protective cover and thus also suitable for outdoor mounting. No temperature controller respectively temperature limitation is necessary. The separate thermo switch enables a low temperature monitoring (<160 °C, NO). For electrical connection a junction box with terminals is mounted. The gas sample probe SP180-H has a calibration gas connection as standard according to EN14181 (regulation for calibration of emission monitoring systems) that enables calibration gas feeding via the filter element of the gas sample probe. S elf-regulated electrical heating Alarm contact for low temperature With new isolation cover for outdoor Test gas connection according to EN14181 for test gas feeding via filter element available as standard Insitu probe tube optional The design of the M&C probe version SP180-H guarantees simple mounting, safe operation and problem-free maintenance. Changing the external filter element needs no tools and no disassembling of the sample line. For the change of the filter element the complete filter assembly is removed out of the probe head. Easy checkup of the filter element and the gaskets, cleaning the filter area of the probe head respectively the insitu probe tube without dismounting the sample probe are only a few advantages of the M&C probe. In the heated filter housing out of stainless steel the 2 micron ceramic filter element is located. More filter element materials are available as option. The compact design and the new all-round heat insulation and weather protection ensures an optimized heat distribution as well as safe operation without dew point lower deviation in the filter or flange area. The stainless steel insitu probe tube SP210/ SS (option) is screwed into the DN65 PN6 mounting flange. The maximum operating temperature of the tube out of stainless steel is 600 °C. For long and cold connection pieces or for dew point lower deviations in the process the heated probe tubes SP30-H or SP35-H are used (see 2.15). For solution of specific sampling problems you can find more filter elements, probe tubes and pre-filters in our wide range of M&C probe accessories (see 2.14 and 2.17). The heating of the gas sample probe to 180°C happens with special self-regulated heating elements within a range of 110V to 240V without switching. Technical specifications and illustrations are without obligation, subject to modifications. 11.13 - 1.01.01 M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111

 Open the catalogue to page 1

Technical Data Series SP® Part No. Protective cover Outdoor mounting Degree of protection Sample temperature Sample pressure Ambient temperature Dust load Filter chamber volume Filter element Probe heating Ready for operation Low temperature alarm contact, alarm point Low temperature alarm contact, contact rating Connection sample outlet Connection calibration gas Power supply Power consumption Electrical connection Electrical equipment standard Mounting flange Material of sample contacting parts Dimensions Weight yes IP54 EN60529 max. 600 °C* 0,4 to 6 bar abs. -25 °C to +60 °C max.1 g/m3 70 ml...

 Open the catalogue to page 2

All M&C TechGroup Germany catalogues and technical brochures

  1. FPF-0.1GF

    2 Pages

    En
  2. FP-2GF

    4 Pages

    En
  3. SP2000/V20

    3 Pages

    En
  4. SP2000/PV

    2 Pages

    En
  5. PSP4000-H

    4 Pages

    En
  6. SP3000/Ex

    4 Pages

    En
  7. PSP4000-H/C

    4 Pages

    En
  8. SP3200/EX

    6 Pages

    En
  9. SP3100/EX

    6 Pages

    En
  10. SP2500-H/C/I/BB

    4 Pages

    En
  11. SP2020-H

    2 Pages

    En
  12. SP2200-H/C/I/BB

    2 Pages

    En
  13. SP2300-H

    4 Pages

    En
  14. SP10-H

    3 Pages

    En
  15. SP10

    3 Pages

    En
  16. SP2100-H

    2 Pages

    En
  17. SP210-H/W

    2 Pages

    En
  18. SP52/53

    2 Pages

    En

Archived catalogues

  1. SP3000/EX

    4 Pages

    En