Oxygen Analyser type PMA100 - M&C TechGroup Germany - #3

/ 3


catalogue search
P. 01
P. 02
P. 03
Pages:


See other catalogues for M&C TechGroup Germany

Text version of the page
9-3.12 M&C | TechGroup Germany GmbH Rehhecke 79, D-40885 Ratingen info@mc-techgroup.com www.mc-techgroup.com Fon +49 (0)2102 935-0 Fax +49 (0)2102 935-111 Technical Data W A R N I N G ! I M P O R T A N T ! An external fine filter must always be used at the gas inlet of the analyser. Depending on the composition of the sample gas, it may be necessary to use a sample conditioning system. Without precautions, the analyser is only suitable for measuring of non-hazardous gases or gasmixtures in non-hazardous areas. Version PMA 100 microprocessor based oxygen analyser in 19"-housing Part No. 03A3000 : PMA 100 power supply 230V 50Hz, 4-20mA; 03A3000a = 115V 60Hz Measuring ranges 4 linear measuring ranges free selectable, lowest span 1%, basis selection* 0-1, 0-10, 0-25 and 0-100 vol. O2. manual, automatic or remote range control and range indication is possible Indication two line 16-sign LCD display, resolution 0,01vol.% O2, continuous O2 indication and call off Text illustration optional in English, French or German O2-transducer temperature, mA-signal, measuring range, time, date, failure-/alarm information, process pressure Output signals selection: isolated 0-20, 2-20, 4-20*, 4-20,5mA for the selected range, max. load 500Ù. interface RS232 type AK-communication protocol - bi-directional, option interface RS485 type Relay outputs free configurable 4 potential free relay contacts NO, contact rating max. 48VDC, 500mA, 15W Binary outputs drive of 3 external solenoid valves for calibration, 3x 24VDC, max. 400mA Binary inputs free configurable potential free, 4x 12-24VDC, max. 20mA or internal supply voltage 12 VDC Flow alarm thermo-conductive sensor, mounted downstream O2-measuring cell Status alarm for min. flow alarm, O2-transducer temperature < 50 °C, central processing unit failure, pressure sensor: LED indication and potential free contact output, NO, max. 48VDC, 500mA, 15W and mA-output indication - example 22mA Alarm contact for exceed/remain measuring range, truncate calibration, external alarm, alternatively oxygen level alarms: LED indication and potential free contact output, NO, max. 48VDC, 500mA, 15W Response time for 90% FSD < 3 seconds at 60 Nl/hr air Accuracy after calibration deviation ± 1% of 2-100% span, ± 2% of 1% span Reproducibility deviation < 1% of span Influence of ambient temperature no influence up to 50 °C Influence of barometric- or process pressure no influence within the range of 0,6 up to 1,6bar abs. with integrated pressure compensation Influence of sample gas flow variation in gas flow between 0-60 Nl/hr air will cause a difference of < 0,1 vol.% O2 Sample gas inlet pressure 0,01 up to 0,6 bar g, (PMA 100 requires positive pressure for adequate flow rate, no pump inside) Sample gas outlet pressure recommendation: discharge freely into atmosphere; however max. 0,6 to 1,6 bar abs. Flow rate of sample gas 25-60 Nl/hr air Temperature of sample gas -10 °C up to +50 °C dry gas O2-transducer temperature fixed at +55 °C Ambient temperature -10 °C up to +50 °C Storage temperature -20 °C up to +60 °C, relative humidity 0-90% RH Power supply internal power unit for 230VAC standard or 115VAC available (a) +/- 10%, 40-60Hz, 35VA Electrical connections mains supply: 3-pole chassis plug with 2 m cable; signals: 4x Sub-D plug Materials in contact with sample gas Platinum, Epoxy resin, glass, FPM, Stainless Steel 316Ti, PTFE, PVDF Sample gas connection 1/8" NPT internal thread*, option with tube connector DN 4/6 /PVDF available, Part No. 05V1045 Protection / electrical standard IP 40 EN 60529 / EN 61010 Housing / front colour 19 inch rack mounting with front handles / grey RAL 7032 Dimension / weight height 4U, width 84HP, depth 350 mm + approx. 60 mm installation space / approx. 11 kg *standard

pageCatalog pdf di En 2012-05-22-30