2-1.1 M&C | TechGroup Germany GmbH Rehhecke 79, D-40885 Ratingen info@mc-techgroup.com www.mc-techgroup.com Fon +49 (0)2102 935-0 Fax +49 (0)2102 935-111 Basic versions and options (choice) Basic executions Data sheet Version Part-No. Basic execution, non-heated, without weather protection shield, material SS 316Ti SP2000 20 S 1000 Basic execution, heated to 0-180 °C ,with weather protection shield, material SS 316Ti SP2000-H 20 S 2000 Basic execution, heated to 0-180 °C, , with weather protection shield, material PTFE 2-1.1.3 SP2300-H 20 S 3000 Basic execution, heated to 0-180 °C, , with weather protection shield, material Titanium SP2400-H 20 S 3500 Options integrated in the gas sample probe (extract) Power supply 115V/60Hz /115V 20 S 9030 Top of filter case with PTFE-rings and seals of PTFE 2-1.1.2 /7aT 20 S 9010 Second outlet for sample gas 1/4" NPTi /2x 20 S 9015 Back purge/calibration gas valve, opening pressure 0,7 bar, pipe 6 mm, blow back and test gas feeding via filter chamber /R 20 S 9045 Back purge/calibration gas valve for SP2400-H, opening pressure 0,7 bar, 1/4" NPTi, blow back and test gas feeding via filter chamber /R-Ti 20 S 9048 Fiber glass filter element 0,1GF150, filter porosity 0,1 ìm, sealing PTFE 2-1.1.2 /GF150 20 S 9020 Spec. filter housing lid and unscrewed cartridge incl. spun glass filling, sealing FPM, Novapress 2-1.1.2 /FW 20 S 9047 Spec. filter housing lid and unscrewed cartridge incl. spun glass filling for 320 °C, sealing graphit 2-1.1.2 /FW 320 20 S 9046 Electrical heating of the exernal filter to 0-320 °C 2-1.2.8 /H320 20 S 9021 Execution for max. 25 bar operating pressure, mounting flange DN50 PN25 /HP 20 S 9017 Gas pre-heater GVW1, material SS304 /GVW1 20 S 9058 Connection of the gas pre-heater to valve ”R” and to gas inlet /GVW 20 S 9062 PT00 sensor instead of the thermostat, without temp. controller /PT100 20 S 9025 Thermoelement FE-CuNi ( type J) instead of thermostat, without temp. controller /Fe-CuNi 20 S 9027 Thermoelement Ni-CrNi (type K) instead of thermostat, without temp. controller /Ni-CrNi 20 S 9028 Second PT100 sensor /2-PT100 20 S 9026 Execution with electrical safety separation according VDE106T101 in connection with thermostat /ST 20 S 9031 Steam heating, without controller and valves 2-1.2.10 /D 20 S 9033 Adapter flange size DN..PN6 or ANSI..150 lbs /DN 20 S 9004 Mounting fitting R2"a or 2"-NPTa instead of the mounting flange /SO1 20 S 9005 Integrated 2-way ball valve with lock function in the inlet 2-1.3.5/2-1.4.5 /VA 20 S 9050 Integrated 3-way ball valve with T-function in the inlet 2-1.3.5/2-1.4.5 /3VA 20 S 9325 Integrated 2-way ball valve with lock function in the inlet, up to 320 °C 2-1.3.5/2-1.4.5 /VA320 20 S 9053 Integrated 3-way ball valve with T-function in the inlet, up to 320 °C 2-1.3.5/2-1.4.5 /3VA320 20 S 9330 Pneumatic drive for ball valves VA and 3VA, 2 operating states 2-1.3.5/2-1.4.5 /MS1 20 S 9055 Pneumatic drive for valves VA 320°C and 3VA 320 °C, 2 operating states 2-1.3.5/2-1.4.5 /MS3 20 S 9056 Electrical actuating drive for ball valves VA and 3VA, 2 operating states, 230V/50Hz 2-1.4.10 /EA230 20 S 9342 Electrical actuating drive for ball valves VA and 3VA, 2 operating states, 115V/60Hz 2-1.4.10 /EA115 20 S 9342a Electrical actuating drive for ball valves VA and 3VA, 2 operating states, 24V DC 2-1.4.10 /EA24 20 S 9342d Filter housing lid for high flowrate with filter element 0,1GF /HF 20 S 9016 260 160 207 340 110 ..14 103 1/4"NPTi 345 Power Alarm contact Tu <-30°C Tset To >+30°C 0-180°C Sample outlet (115V,60Hz) 230V,50Hz N 1 2 5 L L' 3 4 6 7 8 9 Basic version

pageCatalog pdf di En 2012-02-07-17