Gas sample probe SP2000-H - M&C TechGroup Germany - #2

/ 4


catalogue search
P. 01
P. 02
P. 03
P. 04
Pages:


See other catalogues for M&C TechGroup Germany
You may also be interested in

Needle valve, Filter, Solenoid valve, Diaphragm pump, Converter


Text version of the page
2-1.1 M&C | TechGroup Germany GmbH Rehhecke 79, D-40885 Ratingen info@mc-techgroup.com www.mc-techgroup.com Fon +49 (0)2102 935-0 Fax +49 (0)2102 935-111 Dimensions SP2000-H basic version with options (Examples) Dimensions in mm Tu<-30°C 0-180°C To>+30°C 3456789 LL' 1 N 2 Power 230V,50Hz (115V,60Hz) Cal. gas (Backflush) Sample outlet* Second sample outlet Tref. Alarm contact Backflush G1/4"i (Cal. gas) Actuator pressure inlet *Standard 100 345 1/4"NPTi ø 6 ø 14 110 ø 130 340 207 260 Gas Sample Probe Version SP2000 SP2000-H SP2300-H SP2400-H Part No. 20S1000 20S2000 20S3000 20S3500 Protective cover no yes yes yes Degree of protection IP54 EN60529 Filter housing material Stainless steeel 316* PTFE Titanium Sealing materials FPM* /7aT** = PTFE /H320** = graphite Probe flange sealing material Novapress Insitu probe tube/prefilter Optional Sample pressure max. 0,4-6 bar* abs., /7aT**= 2 bar abs., /HP** = 25 bar abs. 2 bar abs. 0,4-6 bar abs. Ambient temperature 20 °C to +180 °C -20 °C to +60 °C*** /PT100, /Fe-CuNi, /Ni-CrNi** = -20°C to +80°C Filter chamber volume 120 cm3 Filter element, porosity S-2K150= Ceramic*, 2micron, /F-0, 1GF150= Glass fibre**, 0,1 micron, /FW= Spun glass** Thermostat, Temperature adjustment 0-180°C* /H320**= 0-320°C /PT100** /Fe-CuNi** /Ni-CrNi** Ready for operation after 40min /H320** = after 60min Low temperature alarm contact* Contact rating: 250V, 3A~, 0,25A= Alarm point: ÄT 30°C Sample gas outlet connection 1x 1/4“ NPTi* tube connectors ø 6, 8 or 10 mm** /H320**= 6 mm Backflush/Test gas connection 1/4“ NPTi* /R**, /H320**= tube ø 6 mm Power supply 230V 50/60 Hz, 800W /115V** = 115V 60Hz, 800W (fuse protection 10A) Electrical connections Terminals max. 4mm2, 2x PG 13,5 cable gland Electrical equipment standard EN 61010, EN 60519-1 Mounting flange DN65 PN6-B >DN or ANSI possible** /HP** = DN50 PN25 Mounting flange material SS316Ti PTFE Titanium Weight 7 kg* 15,4 kg* 15,4 kg* 14,5kg* ÄP and T90 at flow of: 100 200 500 1000 1500 3000 (only /HF) Nl/hr ÄP with new filter element S-2K150/GF150 0,007 0,005 0,02 0,058 0,135 0,240/0,225 bar T90-time for SP2000-H without tube 6 3,5 1 <0,5 <0,5 <0,5 s Differential pressure and T90-time Technical Data * Standard ** Options (/H320 not for SP2300-H, /7aT** not for SP2300-H and SP2400-H) *** In case of higher ambient temperatures use option PT100 (Part No. 20S9025) or thermocouple Fe-CuNi respectively Ni-CrNi (Part No. 20S9027 resp. 20S9028) instead of the thermostate controller. Then, an additional electronic temperature controller (see data sheet 2-5.1) is necessary.

pageCatalog pdf di En 2012-02-07-17