Application
This unit provides completely pre-installed
sample gas conditioning for continuous use
and can excellently be integrated into gas
analysis systems. Its compact construction
means that it takes up only little space.
The CSS units are ready for use within a
few minutes. This, at last, makes the usual
time-consuming procurement of individual
components and assembly superfluous.
Examples of applications for CSS... sample
gas conditioning units: flue gas and process
gas conditioning. For special problems such
as aerosols, various solvents, explosive gases
or mounting in hazard areas, we can provide
you with other solutions.
Description
The M&C gas conditioning units CSS and
CSS-3 are compact, low-maintenance, selfmonitoring
and completely equipped units
(s. page 3) suitable for standard applications.
Toggle switches for the different functions
are located on the front panel:
EXTERNAL-INTERNAL ON
PUMP OFF PUMP ON
MEASURE CHECK
SAMPLE GAS TEST GAS
ZERO GAS SPAN GAS
With an optional 4-position rotary switch
more then one calibration gas can be
selected. Active functions are indicated by
LEDs.
All functions of the CSS... can be controlled
externally with potential-free switch contacts
of an automatic calibration device,
which in some cases are all integrated into
analysers.
The gas pump is incorporated in an automatic
interlock circuit and is only switched
on when the electro gas cooler reaches an
operating temperature of <+8 C.
19"- Gas Conditioning Unit Serie CSS
Version CSS for max. 150Nl/hr
Version CSS-3 for max. 350Nl/hr
Special Features
Completely pre-installed and
operational within 10 minutes
Compact construction, takes up little
space
Self-monitoring and low
maintenance
Up to 5 calibration gases manually or
externally switchable
Outlet dew point adjustable from
+2 C to +15 C
Dew point stability 0,1 C
Optimum reliability
In addition, the liquid alarm switches the
gas pump and the inlet solenoid valve off
automatically in the event of failure.
Great importance has been attached to
the unit's maintenance-friendly design.
The required maintenance can be easily
accessed via a removable front sub-panel
without dismantling the entire system.
The gas conditioning systems CSS... in the
19" plug-in unit can be supplied for operation
at 230V or 115V AC mains supply.
For calibration of the complete analysis
system it is possible to give test gases via
gas conditioning unit CSS-3/C with
a special piping to the sample probe
(SP2000-H/R).
CSS
|
|