Selector Valves
w Fluïd Controls Inc.
The Solution For High Flow and High Pressure Requirements
Features & Benefits
- Flows up to 240 gpm
- 5000 psi (6000 psi intermittent)
- Pneumatic, hydraulic or solenoid operated
- Full Cartridge Style Valving
- Low Leakage
dm
'EH
STANDARD 3-WAY SCHEMA TIC
cous CD STANDARD ^WAY SCHEMATIC
■-M t-î-
; -:• •:• o c
Additional Information
'«« |C;D: STANDARD B-WAY 1MTH RELIEFS & ANT1-CAV SCHEMATIC
STANDARD 8-WAY SCHEMATIC
AN ports can be pressurized up to 3000 psi for aluminum and 5000 psi for ductile iron. Maximum leakage is 5 drops per minute.
Shifting of valve is not affected by pressure differential in working lines. A separate connection to tank for the drain is recommended.
Also a 300 psi minimum hydraulic pressure differential between the pilot & drain must be maintained for proper opération.
Back pressure in the tank line is additive to the relief valves by up to 5.5 times the valve setting. Relief adjustment ranges up to 6000 psi.
u^viç* rure rte* l l y
Turn screw clockwise to reduce setting.
Working Lines = SAE 16 Drain, Pilot & TP = SAE 6